MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.pacs.2026.100865

Медицинская библиотека · Photoacoustics · 2026

Rapid photoacoustic trace gas sensor for online end-tidal CO monitoring in exhaled breath.

Geng Xiao, Zhao Tianbai, Yu Qiwen, Yang Xiu, Liu Lei, Liang Yize, Yin Xukun, Xu Huailiang

СтатьяПеревод пока не подготовлен

Аннотация

Online detection of exhaled breath biomarkers has attracted increasing attention because of its noninvasive, real-time, and point-of-care diagnostic potential. End-tidal carbon monoxide (ETCO) is an important breath biomarker associated with smoking behavior, neonatal hemolysis, and cardiovascular diseases. Here, we report a differential photoacoustic spectroscopy (PAS) sensor for rapid and highly sensitive online ETCO monitoring. A compact 3D-printed dual-channel differential resonant photoacoustic cell (DPAC), with an effective sample volume of only 2.5 mL, was developed to enhance acoustic signal collection while suppressing common-mode noise. The optimized DPAC exhibited an acoustic resonance frequency of 3726.94 Hz, corresponding to a laser current modulation frequency of 1863.47 Hz for second-harmonic detection, with a quality factor of 26. A quantum cascade laser targeting the CO absorption line at 2176.1 cm-1 was used as the excitation source. The sensor exhibited excellent linearity over the concentration range of 0-1000 ppm, with an R2 value exceeding 0.9979, enabling both ambient-level and highly elevated CO measurements on a single platform. A detection limit of 30.6 ppb was achieved at a lock-in time constant of 1 s. Breath measurements from five smokers and five non-smokers showed clear discrimination between the two groups. The smokers exhibited an average ETCO concentration of 21.4 ppm, with all measured values higher than 13.2 ppm, whereas the non-smokers showed an average ETCO concentration of 3.3 ppm, with a maximum value below 3.8 ppm. The proposed PAS sensor combines ppb-level sensitivity and a wide dynamic range, providing a promising platform for real-time breath analysis and preliminary ETCO monitoring.

Для цитирования: Geng Xiao, Zhao Tianbai, Yu Qiwen, Yang Xiu, Liu Lei, Liang Yize, Yin Xukun, Xu Huailiang. Rapid photoacoustic trace gas sensor for online end-tidal CO monitoring in exhaled breath.. Photoacoustics. 2026. DOI: 10.1016/j.pacs.2026.100865.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.