MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1152/ajpheart.00828.2014

Медицинская библиотека · American journal of physiology. Heart and circulatory physiology · 2015

Strain and strain rate by speckle-tracking echocardiography correlate with pressure-volume loop-derived contractility indices in a rat model of athlete's heart.

Kovács Attila, Oláh Attila, Lux Árpád, Mátyás Csaba, Németh Balázs Tamás, Kellermayer Dalma, Ruppert Mihály, Török Marianna, Szabó Lilla, Meltzer Anna, Assabiny Alexandra, Birtalan Ede, Merkely Béla, Radovits Tamás

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Contractile function is considered to be precisely measurable only by invasive hemodynamics. We aimed to correlate strain values measured by speckle-tracking echocardiography (STE) with sensitive contractility parameters of pressure-volume (P-V) analysis in a rat model of exercise-induced left ventricular (LV) hypertrophy. LV hypertrophy was induced in rats by swim training and was compared with untrained controls. Echocardiography was performed using a 13-MHz linear transducer to obtain LV long- and short-axis recordings for STE analysis (GE EchoPAC). Global longitudinal (GLS) and circumferential strain (GCS) and longitudinal (LSr) and circumferential systolic strain rate (CSr) were measured. LV P-V analysis was performed using a pressure-conductance microcatheter, and load-independent contractility indices [slope of the end-systolic P-V relationship (ESPVR), preload recruitable stroke work (PRSW), and maximal dP/dt-end-diastolic volume relationship (dP/dtmax-EDV)] were calculated. Trained rats had increased LV mass index (trained vs. control; 2.76 ± 0.07 vs. 2.14 ± 0.05 g/kg, P < 0.001). P-V loop-derived contractility parameters were significantly improved in the trained group (ESPVR: 3.58 ± 0.22 vs. 2.51 ± 0.11 mmHg/μl; PRSW: 131 ± 4 vs. 104 ± 2 mmHg, P < 0.01). Strain and strain rate parameters were also supernormal in trained rats (GLS: -18.8 ± 0.3 vs. -15.8 ± 0.4%; LSr: -5.0 ± 0.2 vs. -4.1 ± 0.1 Hz; GCS: -18.9 ± 0.8 vs. -14.9 ± 0.6%; CSr: -4.9 ± 0.2 vs. -3.8 ± 0.2 Hz, P < 0.01). ESPVR correlated with GLS (r = -0.71) and LSr (r = -0.53) and robustly with GCS (r = -0.83) and CSr (r = -0.75, all P < 0.05). PRSW was strongly related to GLS (r = -0.64) and LSr (r = -0.71, both P < 0.01). STE can be a feasible and useful method for animal experiments. In our rat model, strain and strain rate parameters closely reflected the improvement in intrinsic contractile function induced by exercise training.

Для цитирования: Kovács Attila, Oláh Attila, Lux Árpád, Mátyás Csaba, Németh Balázs Tamás, Kellermayer Dalma, Ruppert Mihály, Török Marianna, Szabó Lilla, Meltzer Anna, Assabiny Alexandra, Birtalan Ede, Merkely Béla, Radovits Tamás. Strain and strain rate by speckle-tracking echocardiography correlate with pressure-volume loop-derived contractility indices in a rat model of athlete's heart.. American journal of physiology. Heart and circulatory physiology. 2015. DOI: 10.1152/ajpheart.00828.2014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.