DOI 10.1016/j.radi.2025.103197
Efficacy of antiperistaltic agents in improving image quality in pelvic magnetic resonance imaging: A systematic review and meta-analysis.
Аннотация
INTRODUCTION
Anti-peristaltic agents are used in pelvic Magnetic Resonance Imaging (MRI) to minimise bowel motion and enhance image quality. Motion influences image quality and has also been reported as a major cause of artefacts in pelvic MRI. However, the findings on the use of these agents are equivocal, with some studies reporting beneficial effects, while others observed no effects. The systematic review and meta-analysis evaluated and summarised the effectiveness of these agents in enhancing image quality and their overall impact on diagnostic accuracy.
METHODS
This review screened articles reporting on the use of anti-peristaltic agents in pelvic MRI following the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA_2020) flow chart. The articles were obtained from the online databases of PubMed, ScienceDirect, and Cochrane Library, including grey literature. The quality of each included article was evaluated using the Joanna Briggs Institute's critical appraisal checklist. The included articles were analysed qualitatively and quantitatively by meta-analysis using the Review Manager (RevMan) version 5.4 (where applicable).
RESULTS
A total of 13 articles were included in the review following title/abstract and full-text screening of the hits obtained from the databases and grey literature. There were wide variations in the dosage of anti-peristaltic agents (1-50 mg) administered, and MRI scanner types (3T:7, 1.5T:4, combined (1.5T and 3T):1, and 1T:1) reported across studies. A meta-analysis of 4 articles exhibited heterogeneity across the studies, with no significant difference irrespective of whether an anti-peristaltic agent was used or not to improve image quality (Z = 1.36; p = 0.17).
CONCLUSION
It was concluded that there is conflicting or no evidence to support the use of anti-peristaltic agents for improving image quality in pelvic MRI. Nevertheless, the review identified influencing variables such as the dosage of anti-peristaltic agents, MRI protocols, and scanners.
IMPLICATIONS FOR PRACTICE: The review indicated that the use of antiperistaltic agents in pelvic MRI to improve image quality is equivocal, calling for more research in the study area.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.