MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm11072003

Медицинская библиотека · Journal of clinical medicine · 2022

Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis.

Lind Alexander, Jánosi Rolf Alexander, Totzeck Matthias, Ruhparwar Arjang, Rassaf Tienush, Al-Rashid Fadi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) improves the survival and life quality of nonagenarian patients with aortic stenosis. Stroke remains one of the most worrisome complications following TAVR. Cerebral embolic protection devices (CEPDs) may reduce neurological complications after TAVR. This study evaluated the safety and efficacy of CEPDs during TAVR in nonagenarian patients.

METHODS

Between January 2018 and October 2021, 869 patients underwent transfemoral TAVR (TF-TAVR) at our center. Of these, 51 (5.9%) patients were older than ninety years. In 33 consecutive nonagenarian patients, TF-TAVR was implanted without CEPDs using balloon-expandable valves (BEVs) and self-expandable valves (SEVs). Eighteen consecutive nonagenarians underwent TF-TAVR using a CEPD (CP group). Follow up period was in-hospital or 30 days after the procedure, respectively.

RESULTS

Minor access site complications occurred in two patients (3.9%) and were not CEPD-associated. Postinterventional delirium occurred in nine patients (17.6%). Periprocedural minor non-disabling stroke and delirium occurred in ten patients (19.6%). Periprocedural major fatal stroke occurred in two patients in the BEV group (3.9%). Two patients in the BEV group died due to postinterventional pneumonia with sepsis. The mortality rate was 7.8%. The results did not differ between the groups.

CONCLUSIONS

Age alone is no longer a contraindication for TAVR. CEPD using the Triguard 3 system in nonagenarian TAVR patients was feasible and safe and did not increase access site complications.

Для цитирования: Lind Alexander, Jánosi Rolf Alexander, Totzeck Matthias, Ruhparwar Arjang, Rassaf Tienush, Al-Rashid Fadi. Embolic Protection with the TriGuard 3 System in Nonagenarian Patients Undergoing Transcatheter Aortic Valve Replacement for Severe Aortic Stenosis.. Journal of clinical medicine. 2022. DOI: 10.3390/jcm11072003.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.