Bale Reto J, Laimer Ilse, Martin Arno, Schlager Andreas, Mayr Christoph, Rieger Michael, Czermak Benedikt V, Kovacs Peter, Widmann Gerlig
Аннотация
OBJECTIVE: Ablative neurosurgical treatment of trigeminal neuralgia, including percutaneous radiofrequency thermocoagulation, requires cannulation of the foramen ovale. To maximize patient security and cannulation success, a frameless stereotactic system was evaluated in a phantom study, a cadaveric study, and a preliminary clinical trial.
METHODS: Frameless stereotaxy using an optical navigation system, an aiming device, and a noninvasive vacuum mouthpiece-based registration and patient fixation technique was used for the targeting of a test body based on 1-, 3-, and 5-mm axial computed tomographic slices and of the foramen ovale in three cadavers and 15 patients based on 3-mm axial computed tomographic slices.
RESULTS: The mean normal (x/y) localization accuracy/standard deviation (n = 360) was 1.31/0.67 mm (1-mm slices), 1.38/0.65 mm (3-mm slices), and 1.84/0.96 mm (5-mm slices). Significantly better results were achieved with 1- and 3-mm slices when compared with 5-mm slices (P < 0.001). The foramen ovale (3 x 6 mm) was successfully cannulated at the first attempt in all cadavers and patients, which indicates clinical localization accuracies better than 1.5 mm in the anteroposterior and 3 mm in the medial-lateral directions.
CONCLUSION: Based on the noninvasive Vogele-Bale-Hohner vacuum mouthpiece, there is no need for invasive head clamp fixation. Imaging, real laboratory simulation, and the actual surgical intervention can be separated in time and location. The presented data suggest that frameless stereotaxy is a predictable and reproducible procedure, which may enhance patient security and cannulation success independent of the surgeon's experience.
METHODS: Frameless stereotaxy using an optical navigation system, an aiming device, and a noninvasive vacuum mouthpiece-based registration and patient fixation technique was used for the targeting of a test body based on 1-, 3-, and 5-mm axial computed tomographic slices and of the foramen ovale in three cadavers and 15 patients based on 3-mm axial computed tomographic slices.
RESULTS: The mean normal (x/y) localization accuracy/standard deviation (n = 360) was 1.31/0.67 mm (1-mm slices), 1.38/0.65 mm (3-mm slices), and 1.84/0.96 mm (5-mm slices). Significantly better results were achieved with 1- and 3-mm slices when compared with 5-mm slices (P < 0.001). The foramen ovale (3 x 6 mm) was successfully cannulated at the first attempt in all cadavers and patients, which indicates clinical localization accuracies better than 1.5 mm in the anteroposterior and 3 mm in the medial-lateral directions.
CONCLUSION: Based on the noninvasive Vogele-Bale-Hohner vacuum mouthpiece, there is no need for invasive head clamp fixation. Imaging, real laboratory simulation, and the actual surgical intervention can be separated in time and location. The presented data suggest that frameless stereotaxy is a predictable and reproducible procedure, which may enhance patient security and cannulation success independent of the surgeon's experience.