Comparison of liver T1 estimates generated by breath-hold 3D FSPGR and free-breathing 3D radial stack-of-stars FSPGR variable flip angle T1 mapping sequences.

Xu Haiyun, Hou Zhijun, Zhang Ming, Guo Ran, Zhang Jialu, Fu Guifeng, Wen Qingqing, Li Zehua, Tao Feng, Yang Shuohui

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the feasibility of using the free-breathing (FB) radial stack-of-stars fast spoiled gradient recalled-echo (FSPGR) sequence as an alternative to the conventional breath-hold (BH) FSPGR sequence for hepatic T1 mapping across the clinical range of body mass index (BMI).

METHODS

From 07/2024 to 10/2024, 75 participants who underwent both FB and BH FSPGR were analyzed. Participants were stratified into 3 BMI groups. BH IDEAL IQ was also collected to enable PDFF to be evaluated. Quantitative assessments involved whole-liver T1 estimates, volumes, PDFF and the ratio of |T1liver-T1sat|/T1liver. A five-point Likert scale was used for qualitative assessments.

RESULTS

The ratios of |T1liver-T1sat|/T1 liver in FB T1 mapping were higher than those of BH T1 mapping in the overall population and obese group (p both < 0.05). No significant difference was found in liver T1 estimates in patients with BH failure between sequences (p>0.05). FB T1 mapping outperformed BH in artifact scores for the obese group (p = 0.015). Of the 3 groups, the obese group exhibited the greatest amount of artifact in BH FSPGR T1 mapping (p < 0.05). The FB T1 mapping demonstrated superior performance in minimizing artifacts in the lower liver region in persons with BH failure [4 (4, 5) vs. 3 (3, 4), p < 0.001].

CONCLUSION

For overweight and obese patients with difficulty holding their breath during abdominal scanning, VFA FB radial stack-of-stars FSPGR T1 mapping served as a complementary and alternative method to BH sequence.

Для цитирования: Xu Haiyun, Hou Zhijun, Zhang Ming, Guo Ran, Zhang Jialu, Fu Guifeng, Wen Qingqing, Li Zehua, Tao Feng, Yang Shuohui. Comparison of liver T1 estimates generated by breath-hold 3D FSPGR and free-breathing 3D radial stack-of-stars FSPGR variable flip angle T1 mapping sequences.. European journal of radiology open. 2026. DOI: 10.1016/j.ejro.2026.100790.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.