MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/dc.24617

Медицинская библиотека · Diagnostic cytopathology · 2020

Axillary lymph node metastasis: Fine-needle aspiration biopsy sensitivity as a function of node size, percent replacement of lymph node by tumor and tumor deposit size.

Layfield Lester J, Zhang Tao, Esebua Magda, Schmidt Robert

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Fine-needle aspiration (FNA) is commonly used to investigate lymphadenopathy of suspected metastatic origin. While diagnostic accuracy of FNA for lymph node disease is well described, the relationship between node size, percent tumor replacement, and size of metastatic deposit with diagnostic accuracy is less well documented.

METHODS

All axillary lymph nodes undergoing ultrasound-guided FNA for suspected breast metastases were correlated with subsequent surgical excision specimens. FNAs were judged as positive or negative for malignancy and the percent of false negative FNAs was correlated with node size, percent tumor replacement and size of metastatic deposit

RESULTS

Sensitivities were calculated for nodes greater than 15 mm (92%), nodes 11 to 14.9 mm (83%), nodes 7 to 10.9 mm (61%), and for nodes less than 7 mm (60%). Sensitivity increases with increasing node size (P = .001). Percent tumor replacement correlated with sensitivity: 90% or greater replacement (85%) 60% to 89.9% replacement (75%), 40% to 59.9% replacement (75%) and less than 39.9% replacement (64%)(P < .001). Metastases size correlated with sensitivity: metastases greater than 10 mm (94%), 6 to 9.9 mm (70%), 4 to 5.9 mm (54%), and less than 4 mm (72%).

CONCLUSIONS

Percentage of false negative FNAs associate with investigation of metastatic disease correlates with node size, size of metastatic deposit and percentage of nodes replaced by tumor. Lymph nodes smaller than 7 mm, deposit diameter less than 6 mm and percentage replacement of less than 40% have the highest percentage of false negative results.

Для цитирования: Layfield Lester J, Zhang Tao, Esebua Magda, Schmidt Robert. Axillary lymph node metastasis: Fine-needle aspiration biopsy sensitivity as a function of node size, percent replacement of lymph node by tumor and tumor deposit size.. Diagnostic cytopathology. 2020. DOI: 10.1002/dc.24617.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.