MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12957-020-01890-z

Медицинская библиотека · World journal of surgical oncology · 2020

Accuracy of CEUS-guided sentinel lymph node biopsy in early-stage breast cancer: a study review and meta-analysis.

Cui Qiuxia, Dai Li, Li Jialu, Xue Jialei

СтатьяМетаанализОбзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate whether preoperative localization of sentinel lymph node (SLN) by contrast-enhanced ultrasound (CEUS) can further improve the accuracy of sentinel lymph node biopsy (SLNB).

METHOD: Collect published literatures or conference reports by searching electronic databases. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) evaluation method is used to evaluate the quality of the screened literatures. The pooled risk ratio of cancer metastasis of SLN identified by CEUS (CE-SLN) compared with SLN not identified by CEUS (nonCE-SLN) is calculated, and the pooled diagnostic accuracy of CE-SLN for pathological status of all SLNs is also evaluated.

RESULT: Through search and screening, a total of 16 studies were included, of which five and seven studies, respectively, entered the meta-analysis of metastatic risk ratio and diagnostic accuracy. The localization rate of preoperative CEUS for sentinel lymph nodes was 70 to 100%. The meta-analysis shows that the risk of metastasis of SLN identified by CEUS is significantly higher than that not identified by CEUS, 26.0% vs 4.6%, and risk ratio (RR) is 6.08 (95% CI 4.17-8.85). In early-stage breast cancer, the pathological status of CE-SLN is a good representative of all SLNs, with a pooled sensitivity of 98% (95% CI 0.94-1.00), pooled specificity of 100% (95% CI 0.99-1.00), diagnostic odds ratio (DOR) of 2153.18 (95% CI 476.53-9729.06), and area under the subject receiver operating characteristic (SROC) curve of 0.9968.

CONCLUSION

In early-stage breast cancer, preoperative localization of SLN by CEUS is expected to further improve the accuracy of sentinel lymph node biopsy (SLNB).

Для цитирования: Cui Qiuxia, Dai Li, Li Jialu, Xue Jialei. Accuracy of CEUS-guided sentinel lymph node biopsy in early-stage breast cancer: a study review and meta-analysis.. World journal of surgical oncology. 2020. DOI: 10.1186/s12957-020-01890-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.