DOI 10.3389/fcvm.2026.1856637

Медицинская библиотека · Frontiers in cardiovascular medicine · 2026

From one to twelve: feasibility and clinical utility of deep learning-derived 12-lead ECGs for remote cardiac monitoring.

Hu Haoyang, Yu Zekai, Qin Feiwei, Yang Fei

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiovascular diseases (CVDs) remain the leading cause of global mortality. While the 12-lead electrocardiogram (ECG) is the clinical gold standard, wearable devices typically provide only single-lead monitoring (Lead I), which lacks the spatial resolution required to detect complex pathologies such as myocardial infarction or ST-segment changes.

OBJECTIVE

This study proposes a deep learning framework capable of reconstructing a full 12-lead ECG from a single-lead input while preserving diagnostic integrity.

METHODS

We developed TONet (Transformer-based Optimization Network), a multi-task framework evaluated on the PTB-XL dataset (n = 21,837). The architecture integrates a Convolutional Neural Network (CNN) encoder to extract local morphological features and a Transformer encoder to capture global temporal dependencies across the cardiac cycle. To ensure clinical validity, the model was trained using a dual-objective loss function, simultaneously optimizing for signal reconstruction (MSE) and multi-label diagnostic classification (BCE) across five diagnostic super-classes.

RESULTS

TONet achieved an overall Pearson Correlation Coefficient (PCC) reaching 0.673 on the independent test set. Clinical agreement assessment via Bland-Altman analysis revealed a negligible per-lead bias (|Bias| ≤ 0.0024 mV across all 11 reconstructed leads), indicating no systematic voltage drift. In terms of diagnostic utility, the reconstructed 12-lead signals achieved a macro-averaged AUROC of 0.821 (95% CI: 0.810-0.831), with per-class AUROCs of 0.874 (NORM), 0.770 (MI), 0.862 (STTC), 0.782 (CD), and 0.815 (HYP). To assess generalisability beyond a single cohort, we additionally performed an independent in-distribution validation on the Chapman-Shaoxing 12-lead ECG database (n = 43,559 quality-controlled recordings), where TONet, retrained from scratch using the identical protocol, achieved an overall PCC of 0.612 (95% CI: 0.552-0.666) and substantially outperformed the linear-regression baseline (PCC = 0.498), confirming that the reconstruction benefit transfers to a second, hardware- and population-distinct cohort.

CONCLUSION

TONet demonstrates that a hybrid CNN-Transformer network with a multi-task reconstruction-plus-classification objective can recover morphologically faithful 12-lead surrogates from a single Lead I drawn from clinical PTB-XL recordings. We position this work as a regularized deep-learning framework for multi-lead reconstruction rather than a deployable clinical device: the reconstructed precordial leads are insufficient for fine-grained ST-elevation myocardial infarction (STEMI) screening, and external validation on true wearable recordings remains essential.

Для цитирования: Hu Haoyang, Yu Zekai, Qin Feiwei, Yang Fei. From one to twelve: feasibility and clinical utility of deep learning-derived 12-lead ECGs for remote cardiac monitoring.. Frontiers in cardiovascular medicine. 2026. DOI: 10.3389/fcvm.2026.1856637.