Feasibility and Efficacy of Mobile Three-Dimensional c-Arm Systems for Single-Stage Localization and Resection of Small Pulmonary Nodules: A Pilot Clinical Trial.

Fang Hsin-Yueh, Cheng Chuan, Chou Pin-Li, Chao Yin-Kai

СтатьяКлиническое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

Hybrid operating rooms (HORs) incorporating robotic C-arm systems facilitate concurrent localization and resection of small pulmonary nodules, albeit with significant cost barriers. Contemporary mobile 3 D C-arm systems may provide superior soft tissue visualization with enhanced economic viability and accessibility. This prospective single-arm clinical pilot trial was designed to assess the technical feasibility, clinical efficacy, and procedural safety of employing mobile 3 D C-arm technology for single-stage localization and excision of small pulmonary nodules.

METHODS

Patients presenting with small and/or deep-seated lung tumors necessitating preoperative localization were eligible for inclusion. Two distinct mobile 3 D C-arm systems (Cios Spin and Ziehm Vision RFD 3 D) were employed. The primary end-points included the rate of successful tumour localization and the time required to complete the localization procedure. Secondary end-points encompassed perioperative complications and radiation exposure.

RESULTS

The study cohort included 41 patients with lung tumors measuring a median diameter of 7.30 mm (interquartile range [IQR]: 5.00-9.20 mm) and a median depth of 10.00 mm (IQR: 2.00-18.00 mm). Successful localization was achieved in 40 patients, yielding a success rate of 97.6%. In one case, inadequate lesion visualization using the mobile 3 D C-arm necessitated localization in a hybrid operating room. The mean localization time was 27.17 ± 10.38 min, and the median radiation exposure was 531.04 μGy m2 (IQR: [297.12-870.98] μGy m2). All patients were successfully discharged, with a median postoperative hospital stay of 3 days (IQR: 3-3 days).

CONCLUSIONS

Our results support the technical feasibility, clinical efficacy, and procedural safety of mobile 3 D C-arm systems for single-stage localization and resection of small pulmonary nodules.

CLINICAL TRIAL REGISTRATION NUMBER: ClinicalTrials.gov identifier: NCT04974632.

Для цитирования: Fang Hsin-Yueh, Cheng Chuan, Chou Pin-Li, Chao Yin-Kai. Feasibility and Efficacy of Mobile Three-Dimensional c-Arm Systems for Single-Stage Localization and Resection of Small Pulmonary Nodules: A Pilot Clinical Trial.. Interdisciplinary cardiovascular and thoracic surgery. 2026. DOI: 10.1093/icvts/ivaf313.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.