Japanese journal of radiology · 2017
Comparison between solid component size on thin-section CT and pathologic lymph node metastasis and local invasion in T1 lung adenocarcinoma.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hayashi Hideyuki, Ashizawa Kazuto, Ogihara Yukihiro, Nishida Akifumi, Matsumoto Keitaro, Yamasaki Naoya, Nagayasu Takeshi, Fukuda Minoru, Honda Sumihisa, Uetani Masataka
Аннотация
OBJECTIVES: To correlate the tumor size and solid component size on thin-section CT (TS-CT) with pathological findings including lymph node (LN) metastasis and local invasion in T1 lung adenocarcinoma.
METHODS: 188 patients with surgically resected T1 lung adenocarcinoma were retrospectively analyzed. Two chest radiologists measured the long-axis and short-axis dimensions of nodules and solid components with a lung and/or a mediastinal window setting (WS) on TS-CT. After analyzing interobserver agreement, average long-axis dimensions of the measured tumors and solid components were correlated with pathological findings.
RESULTS: Seven of 188 patients (3.7%) had pathologic LN-positive metastasis. In patients in whom the long axis of the solid component was <5 mm with a mediastinal WS or <8 mm with a lung WS on TS-CT, no LN metastases were observed, resulting in a positive predictive value (PPV) for predicting a pathologic LN-negative status of 100% with each WS. Based on the same diagnostic criteria, the PPVs for a pathological local invasion (LI)-negative status were 91 (40/44) and 90% (55/61), respectively.
CONCLUSION: Solid component size on TS-CT may have the potential to predict LN-negative or LI-negative status.
METHODS: 188 patients with surgically resected T1 lung adenocarcinoma were retrospectively analyzed. Two chest radiologists measured the long-axis and short-axis dimensions of nodules and solid components with a lung and/or a mediastinal window setting (WS) on TS-CT. After analyzing interobserver agreement, average long-axis dimensions of the measured tumors and solid components were correlated with pathological findings.
RESULTS: Seven of 188 patients (3.7%) had pathologic LN-positive metastasis. In patients in whom the long axis of the solid component was <5 mm with a mediastinal WS or <8 mm with a lung WS on TS-CT, no LN metastases were observed, resulting in a positive predictive value (PPV) for predicting a pathologic LN-negative status of 100% with each WS. Based on the same diagnostic criteria, the PPVs for a pathological local invasion (LI)-negative status were 91 (40/44) and 90% (55/61), respectively.
CONCLUSION: Solid component size on TS-CT may have the potential to predict LN-negative or LI-negative status.