MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12936-021-03902-z

Медицинская библиотека · Malaria journal · 2021

Accuracy of SD Malaria Ag P.f/Pan® as a rapid diagnostic test in French Amazonia.

Pujo Jean Marc, Houcke Stéphanie, Lemmonier Sarah, Portecop Patrick, Frémery Alexis, Blanchet Denis, Djossou Felix, Kallel Hatem, Demar Magalie

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

French Guiana (FG) is a French overseas territory where malaria is endemic. The current incidence rate is 0.74‰ inhabitants, and Plasmodium vivax is widely predominating even though Plasmodium falciparum is still present due to imported cases mainly from Africa. In FG, rapid diagnostic test (SD Malaria Ag P.f/Pan®) is based on the detection of pan-pLDH, PfHRP2, and PfHRP3 antigens, while in South America, the share of deletion of PfHRP2 gene is significantly increasing. Accordingly, the study questions the reliability of RDTs in the Amazonian context.

METHODS

The study is retrospective. It is conducted over 4 years and analysed 12,880 rapid diagnostic tests (RDTs) compared to concomitant Blood Film Tests (BFTs) sampled for malaria diagnosis.

RESULTS

The global assessment of the accuracy of SD Malaria Ag P.f/Pan® in the diagnostic of malaria shows both Positive and Negative Predictive Values (PPV and NPV) higher than 95%, except for PPV in the diagnosis of malaria to P. falciparum (88%). Overall, the concordance rate between RDT and BFT (positive/positive; negative/negative) was 99.5%. The PPV of the RDT in the follow-up of patients diagnosed with P. falciparum was the lowest during the first 28 days. The PPV of the RDT in the follow-up of patients diagnosed with P. vivax was the lowest during the first 21 days. The global sensitivity of SD Malaria Ag P.f/Pan® test was, on average, 96% (88.2-100) for P. falciparum and 93% (90.6-94.2) for P. vivax. The global specificity was 99.8% (99.5-100) for all included species.

CONCLUSION

SD Malaria Ag P.f/Pan® is a reliable rapid test used for the first-line diagnosis in remote healthcare centres. The test results should be interpreted in the light of patient's recent medical history and the date of arrival to FG.

Для цитирования: Pujo Jean Marc, Houcke Stéphanie, Lemmonier Sarah, Portecop Patrick, Frémery Alexis, Blanchet Denis, Djossou Felix, Kallel Hatem, Demar Magalie. Accuracy of SD Malaria Ag P.f/Pan® as a rapid diagnostic test in French Amazonia.. Malaria journal. 2021. DOI: 10.1186/s12936-021-03902-z.