The Safety and Feasibility of Same-Day Discharge After Implantation of MICRA Transcatheter Leadless Pacemaker System.
Аннотация
BACKGROUND
Data suggests that same day discharge after implantation of trans-venous pacemakers is safe and feasible. We sought to determine whether same day discharge was feasible and safe following implantation of Medtronic MICRA leadless pacemakers.
METHODS
We retrospectively identified all patients undergoing MICRA placement at our institution between April 2014 to August 2018 (n=167). Patients were stratified into two groups: those discharged on the same day as their procedure (SD, n=25), and those observed for at least one night in the hospital (HD, n=142). The primary endpoint included a composite of major complications including: access site complications, new pericardial effusion, device dislodgement, and need for device revision up to approximately 45 days of follow up.
RESULTS
SD and HD had similar age (75±13 vs. 75±13 years, p=0.923), prevalence of male sex (49 vs. 44%, p=0.669), and frequency of high-grade heart block as an indication for pacing (38 vs. 32%, p=0.596). There were more Caucasians in the SD group (72 vs. 66%, p=0.038). The rate of the composite endpoint was statistically non-significantly higher in the HD group (3.5% vs. 0.0%, p=1.00). The rates of each individual components comprising the composite endpoint were similar between groups.
CONCLUSIONS
Our data suggest that in appropriately selected patients, same day discharge can occur safely following Micra leadless pacemaker implantation.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.