Delayed presentation of right ventricular lead perforation following defibrillator implantation: a case report.
Аннотация
BACKGROUND
Perforation of a device lead through the myocardium is a recognized complication of cardiac device implantation. The associated morbidity and mortality are significant, even though it is a relatively rare complication. Therefore, it is vital for acute clinicians to be aware of the diagnosis and subsequent management of myocardial perforation.
CASE SUMMARY: We present the case of a 48-year-old woman who presented to the emergency department 1 month following implantable cardioverter-defibrillator implantation with chest and shoulder pain. Initial assessment revealed bilateral pleural effusions and anaemia. Computerized tomography of her chest and abdomen demonstrated a pericardial effusion, but it was transthoracic echocardiography that confirmed the diagnosis of right ventricular perforation. Urgent system revision was undertaken.
DISCUSSION: This case highlights the importance of clinical suspicion and the use of diagnostic echocardiography as an important diagnostic tool in symptomatic patient's post-cardiac device implantation.