MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcv.2019.03.013

Медицинская библиотека · Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2019

Human Herpes-8 virus copy to cell ratio: A diagnostic tool in primary effusion lymphoma.

Carne Simon, Smit Erasmus, Price Nicola, Paul Joel, Guiver Malcolm, Tedder Richard

СтатьяПеревод пока не подготовлен

Аннотация

Primary effusion lymphoma (PEL) is a serious sequel to Human Herpes Virus 8 (HHV8) infection in the immunosuppressed host. Usually requiring a cytological diagnosis, body cavity effusions are often referred for investigation for possible PEL. Although absence of HHV8 effectively refutes this, the presence of HHV8 DNA, though indicative is not diagnostic. Referred effusion and plasma samples from 10 patients with HHV8-related pleural and pericardial effusions were submitted for quantitative investigations. HHV8 DNA and human DNA from unseparated effusion extracts have been quantified allowing estimation of virus-to-cell ratios in effusion fluid. These ratios varied widely between 0.003 and 700. Five fluids had in excess of 106 HHV-8 DNA genome equivalents per ML (GEq/ML), ranging between 18 and 300 million GEq/ML. Four of these five effusions were from patients with cytologically proven PEL and had virus to cell (V:C) ratios between 100 and 700 to 1. The remaining high load effusion exhibited a ratio of 1.6 to 1 and came from a patient with extensive thoracic Kaposi's sarcoma. Five effusion fluids with low viral loads exhibited virus to cell ratios between 0.003 and 0.5. High effusion HHV8 load, though supportive of a diagnosis of PEL is less accurate than using virus to cell ratios.

Для цитирования: Carne Simon, Smit Erasmus, Price Nicola, Paul Joel, Guiver Malcolm, Tedder Richard. Human Herpes-8 virus copy to cell ratio: A diagnostic tool in primary effusion lymphoma.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2019. DOI: 10.1016/j.jcv.2019.03.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.