MedElevator Войти в исследования
← Поиск публикаций

DOI 10.21873/invivo.12777

Медицинская библиотека · In vivo (Athens, Greece) · 2022

Effect of Thickening Powder on Gastrointestinal Losses in Patients With High-output End Jejunostomy Syndrome - Preliminary Results.

Zaczek Zuzanna, Dąbrowska Karolina, Omidi Mohammad, Panczyk Mariusz, Sobocki Jacek

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIM: End jejunostomy syndrome is a type of short bowel syndrome (SBS) in which the jejunum forms the end of the bowel, as a result of resection or exclusion of the ileum and colon. It is associated with a high risk of dehydration, electrolyte imbalance, and malnutrition due to excessive stomal losses.

PATIENTS AND

METHODS

In this retrospective study, we analyzed the medical records of sixteen adult patients with SBS and high-output end jejunostomy syndrome who received thickened fluids during their hospitalization in the home parenteral nutrition unit. The main parameter considered was daily stoma excretion volume, measured by 24-h collection. Values were compared between days when patients drank the daily amount of 600 ml of water, and days when patients ingested the same amount of water but mixed with thickening powder to achieve a mildly thick consistency.

RESULTS

Median volumes of end jejunostomy output were significantly lower when patients consumed the mixture of water and thickening powder, compared with drinking water without additives (550.0 ml/d vs. 811.9 ml/d, p=0.002).

CONCLUSION

These preliminary results demonstrate a potential benefit of thickening powder for the nutritional management of patients with SBS type I, and point to the need for further randomized clinical studies with larger patient groups.

Для цитирования: Zaczek Zuzanna, Dąbrowska Karolina, Omidi Mohammad, Panczyk Mariusz, Sobocki Jacek. Effect of Thickening Powder on Gastrointestinal Losses in Patients With High-output End Jejunostomy Syndrome - Preliminary Results.. In vivo (Athens, Greece). 2022. DOI: 10.21873/invivo.12777.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.