MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ndt/gfm954

Медицинская библиотека · Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association · 2008

Decreased coronary flow reserve in haemodialysis patients.

Niizuma Shinnichiro, Takiuchi Shin, Okada Sadanori, Horio Takeshi, Kamide Kei, Nakata Hiroto, Yoshihara Fumiki, Nakamura Satoko, Kawano Yuhei, Nakahama Hajime, Iwanaga Yoshitaka, Nakatani Satoshi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Coronary flow reserve (CFR) reflects the functional capacity of microcirculation to adapt to blood demand during increased cardiac work.

METHODS

Forty-one patients who had already undergone coronary angiography were studied. They consisted of 21 haemodialysis patients with no significant left anterior descending coronary artery (LAD) stenosis and 20 non-renal failure patients without LAD stenosis. We performed transthoracic Doppler recording of diastolic coronary flow velocity in the LAD at baseline and after maximal vasodilatation by adenosine triphosphate (ATP) infusion. CFR was defined as the ratio of hyperaemic to basal averaged peak flow velocity.

RESULTS

Although the peak coronary velocities during hyperaemia were similar between the two groups, CFR was smaller in haemodialysis (HD) patients than in control subjects (1.96 +/- 04 versus 2.3 +/- 0.5, P = 0.001) due to the higher baseline peak coronary velocities in the former.

CONCLUSIONS

The elevated baseline peak coronary velocity may be caused by cardiac hypertrophy and anaemia in HD patients.

Для цитирования: Niizuma Shinnichiro, Takiuchi Shin, Okada Sadanori, Horio Takeshi, Kamide Kei, Nakata Hiroto, Yoshihara Fumiki, Nakamura Satoko, Kawano Yuhei, Nakahama Hajime, Iwanaga Yoshitaka, Nakatani Satoshi. Decreased coronary flow reserve in haemodialysis patients.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2008. DOI: 10.1093/ndt/gfm954.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.