m+Medelevator.RU
← Поиск публикаций
Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2025

Nipple malposition following nipple sparing mastectomy: Evaluation of secondary correction in prepectoral implant-based breast reconstruction.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ahmed Shahnur, Hajj John P, Ali Iyad S, Danforth Rachel M, Fisher Carla S, Lester Mary E, Hassanein Aladdin H

Аннотация

Ptosis can be a relative contraindication to nipple sparing mastectomy (NSM). Although a mastopexy-type approach can be performed during mastectomy, this requires very well perfused skin flaps and possibly intraoperative adjustments with the oncological breast surgeon. The purpose of this study is to assess risk factors that result in the nipple surgically raised secondarily in standard NSM with prepectoral tissue expander (TE) reconstruction to help guide surgical decision-making and patient counseling. Patients at our center who underwent NSM and immediate prepectoral TE reconstruction were assessed. Patients who had immediate nipple position adjustment during the day of the mastectomy were excluded. Patients were divided into two groups: Group 1 (secondary nipple adjustment during the second stage) and Group 2 (no secondary nipple adjustment). Preoperative sternal notch-to-nipple distance, Regnault classification ptosis grade, brassiere size, and mastectomy weights were assessed. The study included 158 patients: 33 patients in Group 1, 125 patients in Group 2. Grade II ptosis was present in 84.8% (28/33) of Group 1 compared to 58.4% (73/125) of Group 2 (p=0.0044). The average preoperative sternal notch-to-nipple distance for Group 1 was 26.2±2.6 cm compared to 24.7±3.9 cm for Group 2 (p=0.002). There was no difference in preoperative cup size between groups (p=1). The average mastectomy weight in Group 1 was 542.6±207.6 g compared to 449.4±264.3 g (p=0.03). Patients with grade II ptosis, sternal notch-to-nipple >26 cm, and larger breast size who undergo standard NSM are more likely to require secondary nipple correction. The findings can improve patient counseling and expectations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты