Automatic QRS Selvester scoring system in patients with left bundle branch block.

Xia Xiaojuan, Wieslander Björn, Strauss David G, Wagner Galen S, Zareba Wojciech, Moss Arthur J, Couderc Jean-Philippe

Сравнительное исследованиеСтатьяВалидационное исследованиеПеревод пока не подготовлен

Аннотация

AIMS: The Selvester QRS scoring system uses quantitative criteria from the standard 12-lead electrocardiogram (ECG) to estimate the myocardial scar size of patients, including those with left bundle branch block (LBBB). Automation of the scoring system could facilitate the clinical use of this technique which requires a set of multiple QRS patterns to be identified and measured.

METHODS AND

RESULTS

We developed a series of algorithms to automatically detect and measure the QRS parameters required for Selvester scoring. The 'QUantitative and Automatic REport of Selvester Score' was designed specifically for the analysis of ECGs from patients meeting new strict criteria for complete LBBB. The algorithms were designed using a training (n = 36) and a validation (n = 180) set of ECGs, consisting of signal-averaged 12-lead ECGs (1000 Hz sampling) recorded from 216 LBBB patients from the MADIT-CRT. We assessed the performance of the methods using expert manually adjudicated ECGs. The average of absolute differences between automatic and adjudicated Selvester scoring was 1.2 ± 1.5 points. The range of average differences for continuous measurements of wave locations and interval durations varied between 0 and 6 ms. Erroneous detection of Q, R, S, R', and S' waves (oversensed or missed) were 3, 1, 1, 16, and 6%, respectively. Seven percent of notches detected in the first 40 ms were misdetected.

CONCLUSION

We propose an efficient computerized method for the automatic measurement of the Selvester score in patients with the strict LBBB.

Для цитирования: Xia Xiaojuan, Wieslander Björn, Strauss David G, Wagner Galen S, Zareba Wojciech, Moss Arthur J, Couderc Jean-Philippe. Automatic QRS Selvester scoring system in patients with left bundle branch block.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2015. DOI: 10.1093/europace/euv040.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.