Influence of left ventricular lead position relative to scar location on response to cardiac resynchronization therapy: a model study.

Huntjens Peter R, Walmsley John, Ploux Sylvain, Bordachar Pierre, Prinzen Frits W, Delhaas Tammo, Lumens Joost

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: It is unclear how the position of the left ventricular (LV) lead relative to a scar affects the haemodynamic response in patients with dyssynchronous heart failure receiving cardiac resynchronization therapy. We investigated this complex interaction using a computational model.

METHODS AND

RESULTS

The CircAdapt computational cardiovascular system model was used to simulate heart failure with left bundle branch block (LBBB). Myocardial scar was induced in four different regions of the LV free wall (LVFW). We then simulated biventricular pacing (BVP) in each heart, in which LV lead position was varied. The LV lead position leading to maximal acute change in LV stroke volume (SV) was defined as optimal lead position. In LBBB without scar, SV increase was maximal when pacing the LVFW region most distant from the septum. With a scar adjacent to the septum, maximal response was achieved when pacing remote from both the septum and the scar. When the scar was located further from the septum, the BVP-induced increase of SV was small. For all hearts, pacing from the optimal LV lead position resulted in the most homogeneous distribution of local ventricular myofibre work and the largest increase in summed left and right ventricular pump work.

CONCLUSIONS

These computer simulations suggest that, in hearts with LBBB and scar, the optimal LV lead position is a compromise between a position distant from the scar and from the septum. In infarcted hearts, the best haemodynamic effect is achieved when electromechanical resynchronization of the remaining viable myocardium is most effective.

Для цитирования: Huntjens Peter R, Walmsley John, Ploux Sylvain, Bordachar Pierre, Prinzen Frits W, Delhaas Tammo, Lumens Joost. Influence of left ventricular lead position relative to scar location on response to cardiac resynchronization therapy: a model study.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/euu231.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.