MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2014.08.029

Медицинская библиотека · Heart rhythm · 2014

Idiopathic ventricular arrhythmias originating from the moderator band: Electrocardiographic characteristics and treatment by catheter ablation.

Sadek Mouhannad M, Benhayon Daniel, Sureddi Ravi, Chik William, Santangeli Pasquale, Supple Gregory E, Hutchinson Mathew D, Bala Rupa, Carballeira Lidia, Zado Erica S, Patel Vickas V, Callans David J, Marchlinski Francis E, Garcia Fermin C

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The moderator band (MB) can be a source of premature ventricular contractions (PVCs), monomorphic ventricular tachycardia (VT), and idiopathic ventricular fibrillation (IVF).

OBJECTIVE

The purpose of this study was to define the electrocardiographic (ECG) characteristics and procedural techniques to successfully identify and ablate MB PVCs/VT.

METHODS

In 10 patients with left bundle branch block morphology PVCs/VT, electroanatomic mapping in conjunction with intracardiac echocardiography (ICE) localized the site of origin of the PVCs to the MB. Clinical characteristics of the patients, ECG features, and procedural data were collected and analyzed.

RESULTS

Seven patients presented with IVF and 3 presented with monomorphic VT. In all patients, the ventricular arrhythmias (VAs) had a left bundle branch block QRS with a late precordial transition (>V4), a rapid downstroke of the QRS in the precordial leads, and a left superior frontal plane axis. Mean QRS duration was 152.7 ± 15.2 ms. Six patients required a repeat procedure. After mean follow-up of 21.5 ± 11.6 months, all patients were free of sustained VAs, with only 1 patient requiring antiarrhythmic drug therapy and 1 patient having isolated PVCs no longer inducing VF. There were no procedural complications.

CONCLUSION

VAs originating from the MB have a distinctive morphology and often are associated with PVC-induced ventricular fibrillation. Catheter ablation can be safely performed and is facilitated by ICE imaging.

Для цитирования: Sadek Mouhannad M, Benhayon Daniel, Sureddi Ravi, Chik William, Santangeli Pasquale, Supple Gregory E, Hutchinson Mathew D, Bala Rupa, Carballeira Lidia, Zado Erica S, Patel Vickas V, Callans David J, Marchlinski Francis E, Garcia Fermin C. Idiopathic ventricular arrhythmias originating from the moderator band: Electrocardiographic characteristics and treatment by catheter ablation.. Heart rhythm. 2014. DOI: 10.1016/j.hrthm.2014.08.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.