Serial changes in circulating M30 antigen, a biomarker of apoptosis, in patients with acute coronary syndromes: relationship with the severity of coronary artery disease.

Senturk Tunay, Aydinlar Ali, Yilmaz Yusuf, Oral Arzu Yilmaztepe, Ozdabakoglu Osman, Ulukaya Engin

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

Growing evidence has indicated the potential clinical usefulness of measuring different forms of cytokeratin 18 in patient sera (M30 antigen for apoptosis and M65 antigen for necrosis) for distinguishing different forms of cell death. Preliminary data have reported altered levels of cytokeratin 18 fragments in patients with acute coronary syndrome (ACS) and ischemic heart disease. In this study, serum levels of M30 and M65 were measured in 74 patients with ACS [including 17 cases with unstable angina and 57 patients with acute myocardial infarction (AMI)], 25 patients with stable angina, and 23 controls.

METHODS

In patients with ACS, serial measurements of M30 and M65 were obtained, and for each patient, the following values were determined: (i) values at admission, (ii) values obtained 24 h after symptom onset, and (iii) values obtained at 48 h after symptom onset. The severity of coronary atherosclerosis was expressed using the Gensini score.

RESULTS

On admission, M30 and M65 levels in ACS patients were similar to those observed in stable angina patients and control participants. In AMI patients, serum levels of M30 peaked at 24 h and declined thereafter at 48 h. Notably, serum levels of M30 measured at 24 h correlated significantly and positively with the extent of coronary artery disease as measured by the Gensini score in AMI patients (r = 0.253, P<0.05).

CONCLUSION

Serum levels of the apoptotic marker M30 peak at 24 h after AMI and reflects the extent of coronary artery disease in this patient group.

Для цитирования: Senturk Tunay, Aydinlar Ali, Yilmaz Yusuf, Oral Arzu Yilmaztepe, Ozdabakoglu Osman, Ulukaya Engin. Serial changes in circulating M30 antigen, a biomarker of apoptosis, in patients with acute coronary syndromes: relationship with the severity of coronary artery disease.. Coronary artery disease. 2009. DOI: 10.1097/mca.0b013e328330d56a.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.