MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-026-12829-5

Медицинская библиотека · European radiology · 2026

Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis.

Kato Shingo, Azuma Mai, Horita Nobuyuki, Kinoshita Minori, Iwahashi Takumi, Yasuda Naofumi, Sawamura Shungo, Ishiwata Yoshinobu, Utsunomiya Daisuke

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To systematically evaluate the radiation dose, contrast media utilisation, image quality, and diagnostic performance of photon-counting detector CT (PCCT) versus energy-integrating detector CT (EID-CT) in CT pulmonary angiography (CTPA).

MATERIALS AND

METHODS

PubMed, Web of Science, and Cochrane CENTRAL were searched to March 10, 2026. Studies comparing PCCT with EID-CT or reporting PCCT-based CTPA were included. Random-effects meta-analyses evaluated CT dose index volume (CTDIvol), total iodine load (TIL), SNR, and CNR. Sensitivity analyses used the Hartung-Knapp adjustment.

RESULTS

Twelve studies (950 patients) were included. Radiation dose (5 studies, 854 patients) and contrast load (2 studies, 322 patients) were significantly lower with PCCT under standard models: pooled CTDIvol mean difference (MD) was -2.85 mGy (95% CI -5.52 to -0.18) and total iodine load MD was -5.62 gI (95% CI -9.34 to -1.89) (both p < 0.05). However, neither was significant under Hartung-Knapp adjustment (p = 0.113 for CTDIvol; p = 0.208). SNR and CNR showed no significant differences. For chronic thromboembolic disease (2 studies, 109 patients), the pooled sensitivity and specificity of PCCT iodine maps were 92.3% (95% CI 85.4-96.1%) and 83.4% (95% CI 75.2-89.3%), respectively.

CONCLUSION

PCCT-based CTPA shows potential to reduce radiation dose and contrast load versus EID-CT while maintaining image quality. However, under Hartung-Knapp adjustment, differences were not significant, requiring cautious interpretation under high heterogeneity.

KEY POINTS: Question Does photon-counting detector CT (PCCT) reduce radiation dose and contrast media volume in CT pulmonary angiography (CTPA) for pulmonary embolism compared to energy-integrating detector CT? Findings While PCCT-based CTPA shows significant reductions in radiation dose and iodine load under standard random-effects models, these benefits were not statistically significant under conservative sensitivity analyses (Hartung-Knapp adjustment) due to high protocol heterogeneity. Clinical relevance PCCT-based CTPA has the potential to allow for lower radiation dose and contrast media utilisation, which could help minimise the risks of radiation exposure and contrast-induced nephropathy in vulnerable patients, though protocol standardisation is required to confirm these benefits.

Для цитирования: Kato Shingo, Azuma Mai, Horita Nobuyuki, Kinoshita Minori, Iwahashi Takumi, Yasuda Naofumi, Sawamura Shungo, Ishiwata Yoshinobu, Utsunomiya Daisuke. Photon-counting detector CT for CT pulmonary angiography: a systematic review and meta-analysis.. European radiology. 2026. DOI: 10.1007/s00330-026-12829-5.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.