Noninvasive monitoring of a murine model of metastatic pheochromocytoma: a comparison of contrast-enhanced microCT and nonenhanced MRI.

Martiniova Lucia, Kotys Melanie S, Thomasson David, Schimel Daniel, Lai Edwin W, Bernardo Marcelino, Merino Maria J, Powers James F, Ruzicka Jan, Kvetnansky Richard, Choyke Peter L, Pacak Karel

Сравнительное исследованиеСтатьяПоддержка NIH: внешняя программаResearch Support, N.I.H., IntramuralПеревод пока не подготовлен

Аннотация

PURPOSE: To compare contrast-enhanced micro-computed tomography (microCT) and nonenhanced respiratory-triggered magnetic resonance imaging (MRI) in an animal model of metastatic pheochromocytoma. Animal models are becoming important in the study of cancer treatment and imaging is useful in minimizing the number of animals needed and reducing costs associated with autopsies. However, the choice of imaging modality is still evolving.

MATERIALS AND

METHODS

Adult female nude mice were injected by tail vein with a mouse pheochromocytoma (MPC) cell line (MPC 4/30PRR) to create a metastatic model. After optimizing imaging techniques, eight mice were imaged with both respiratory triggered MRI and microCT and the findings were verified histologically.

RESULTS

MicroCT and MRI were approximately equal in their ability to detect hepatic metastases at a size threshold of 350 microm. In the lungs, MRI was more sensitive than microCT, detecting lesions 0.6 mm in diameter versus 1 mm for microCT. Additionally, MRI was more sensitive for lesions in the kidneys, bone, ovaries, and adrenal glands. MRI demonstrated a higher contrast-to-noise ratio (CNR) than microCT.

CONCLUSION

In addition to the advantage of not exposing the animal to ionizing radiation, MRI provided a more complete assessment of the extent of metastases in this model compared to microCT.

Для цитирования: Martiniova Lucia, Kotys Melanie S, Thomasson David, Schimel Daniel, Lai Edwin W, Bernardo Marcelino, Merino Maria J, Powers James F, Ruzicka Jan, Kvetnansky Richard, Choyke Peter L, Pacak Karel. Noninvasive monitoring of a murine model of metastatic pheochromocytoma: a comparison of contrast-enhanced microCT and nonenhanced MRI.. Journal of magnetic resonance imaging : JMRI. 2009. DOI: 10.1002/jmri.21654.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.