MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1200/jco.2006.09.6297

Медицинская библиотека · Journal of clinical oncology : official journal of the American Society of Clinical Oncology · 2007

Superiority of fluorodeoxyglucose positron emission tomography to other functional imaging techniques in the evaluation of metastatic SDHB-associated pheochromocytoma and paraganglioma.

Timmers Henri J L M, Kozupa Anna, Chen Clara C, Carrasquillo Jorge A, Ling Alexander, Eisenhofer Graeme, Adams Karen T, Solis Daniel, Lenders Jacques W M, Pacak Karel

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: Germline mutations of the gene encoding subunit B of the mitochondrial enzyme succinate dehydrogenase (SDHB) predispose to malignant paraganglioma (PGL). Timely and accurate localization of these aggressive tumors is critical for guiding optimal treatment. Our aim is to evaluate the performance of functional imaging modalities in the detection of metastatic lesions of SDHB-associated PGL.

PATIENTS AND

METHODS

Sensitivities for the detection of metastases were compared between [18F]fluorodopamine ([18F]FDA) and [18F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET), iodine-123- (123I) and iodine-131 (131I) -metaiodobenzylguanidine (MIBG), 111In-pentetreotide, and Tc-99m-methylene diphosphonate bone scintigraphy in 30 patients with SDHB-associated PGL. Computed tomography (CT) and magnetic resonance imaging (MRI) served as standards of reference.

RESULTS

Twenty-nine of 30 patients had metastatic lesions. In two patients, obvious metastatic lesions on functional imaging were missed by CT and MRI. Sensitivity according to patient/body region was 80%/65% for 123I-MIBG and 88%/70% for [18F]FDA-PET. False-negative results on 123I-MIBG scintigraphy and/or [18F]FDA-PET were not predicted by genotype or biochemical phenotype. [18F]FDG-PET yielded a by patient/by body region sensitivity of 100%/97%. At least 90% of regions that were false negative on 123I-MIBG scintigraphy or [18F]FDA-PET were detected by [18F]FDG-PET. In two patients, 111In-pentetreotide scintigraphy detected liver lesions that were negative on other functional imaging modalities. Sensitivities were similar before and after chemotherapy or 131I-MIBG treatment, except for a trend toward lower post- (60%/41%) versus pretreatment (80%/65%) sensitivity of 123I-MIBG scintigraphy.

CONCLUSION

With a sensitivity approaching 100%, [18F]FDG-PET is the preferred functional imaging modality for staging and treatment monitoring of SDHB-related metastatic PGL.

Для цитирования: Timmers Henri J L M, Kozupa Anna, Chen Clara C, Carrasquillo Jorge A, Ling Alexander, Eisenhofer Graeme, Adams Karen T, Solis Daniel, Lenders Jacques W M, Pacak Karel. Superiority of fluorodeoxyglucose positron emission tomography to other functional imaging techniques in the evaluation of metastatic SDHB-associated pheochromocytoma and paraganglioma.. Journal of clinical oncology : official journal of the American Society of Clinical Oncology. 2007. DOI: 10.1200/jco.2006.09.6297.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.