MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00330-006-0516-7

Медицинская библиотека · European radiology · 2006

Adrenal metastases: CT-guided and MR-thermometry-controlled laser-induced interstitial thermotherapy.

Vogl Thomas J, Lehnert Thomas, Eichler Katrin, Proschek Dirk, Flöter Julius, Mack Martin G

СтатьяПеревод пока не подготовлен

Аннотация

The aim of the study was to evaluate the feasibility, safety and effectiveness of CT-guided and MR-thermometry-controlled laser-induced interstitial thermotherapy (LITT) in adrenal metastases. Nine patients (seven male, two female; average age 65.0 years; range 58.7-75.0 years) with nine unilateral adrenal metastases (mean diameter 4.3 cm) from primaries comprising colorectal carcinoma (n = 5), renal cell carcinoma (n = 1), oesophageal carcinoma (n = 1), carcinoid (n = 1), and hepatocellular carcinoma (n = 1) underwent CT-guided, MR-thermometry-controlled LITT using a 0.5 T MR unit. LITT was performed with an internally irrigated power laser application system with an Nd:YAG laser. A thermosensitive, fast low-angle shot 2D sequence was used for real-time monitoring. Follow-up studies were performed at 24 h and 3 months and, thereafter, at 6-month intervals (median 14 months). All patients tolerated the procedure well under local anaesthesia. No complications occurred. Average number of laser applicators per tumour: 1.9 (range 1-4); mean applied laser energy 33 kJ (range 15.3-94.6 kJ), mean diameter of the laser-induced coagulation necrosis 4.5 cm (range 2.5-7.5 cm). Complete ablation was achieved in seven lesions, verified by MR imaging; progression was detected in two lesions in the follow-up. The preliminary results suggest that CT-guided, MR-thermometry-controlled LITT is a safe, minimally invasive and promising procedure for treating adrenal metastases.

Для цитирования: Vogl Thomas J, Lehnert Thomas, Eichler Katrin, Proschek Dirk, Flöter Julius, Mack Martin G. Adrenal metastases: CT-guided and MR-thermometry-controlled laser-induced interstitial thermotherapy.. European radiology. 2006. DOI: 10.1007/s00330-006-0516-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.