MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ccd.28147

Медицинская библиотека · Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2019

Left ventricular geometry predicts optimal response to percutaneous mitral repair via MitraClip: Integrated assessment by two- and three-dimensional echocardiography.

Kim Jiwon, Alakbarli Javid, Palumbo Maria Chiara, Xie Lola X, Rong Lisa Q, Tehrani Nathan H, Brouwer Lillian R, Devereux Richard B, Wong Shing Chiu, Bergman Geoffrey W, Khalique Omar K, Levine Robert A, Ratcliffe Mark B, Weinsaft Jonathan W

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To assess impact of left ventricular (LV) chamber remodeling on MitraClip (MClp) response.

BACKGROUND

MitraClip is the sole percutaneous therapy approved for mitral regurgitation (MR) but response varies. LV dilation affects mitral coaptation; determinants of MClp response are uncertain.

METHODS

LV and mitral geometry were quantified on pre- and post-procedure two-dimensional (2D) transthoracic echocardiography (TTE) and intra-procedural three-dimensional (3D) transesophageal echocardiography (TEE). Optimal MClp response was defined as ≤mild MR at early (1-6 month) follow-up.

RESULTS

Sixty-seven degenerative MR patients underwent MClp: Whereas MR decreased ≥1 grade in 94%, 39% of patients had optimal response (≤mild MR). Responders had smaller pre-procedural LV end-diastolic volume (94 ± 24 vs. 109 ± 25 mL/m2 , p = 0.02), paralleling smaller annular diameter (3.1 ± 0.4 vs. 3.5 ± 0.5 cm, p = 0.002), and inter-papillary distance (2.2 ± 0.7 vs. 2.5 ± 0.6 cm, p = 0.04). 3D TEE-derived annular area correlated with 2D TTE (r = 0.59, p < 0.001) and was smaller among optimal responders (12.8 ± 2.1 cm2 vs. 16.8 ± 4.4 cm2 , p = 0.001). Both 2D and 3D mitral annular size yielded good diagnostic performance for optimal MClp response (AUC 0.73-0.84, p < 0.01). In multivariate analysis, sub-optimal MClp response was associated with LV end-diastolic diameter (OR 3.10 per-cm [1.26-7.62], p = 0.01) independent of LA size (1.10 per-cm2 [1.02-1.19], p = 0.01); substitution of mitral annular diameter for LV size yielded an independent association with MClp response (4.06 per-cm2 [1.03-15.96], p = 0.045).

CONCLUSIONS

Among degenerative MR patients undergoing MClp, LV and mitral annular dilation augment risk for residual or recurrent MR, supporting the concept that MClp therapeutic response is linked to sub-valvular remodeling.

Для цитирования: Kim Jiwon, Alakbarli Javid, Palumbo Maria Chiara, Xie Lola X, Rong Lisa Q, Tehrani Nathan H, Brouwer Lillian R, Devereux Richard B, Wong Shing Chiu, Bergman Geoffrey W, Khalique Omar K, Levine Robert A, Ratcliffe Mark B, Weinsaft Jonathan W. Left ventricular geometry predicts optimal response to percutaneous mitral repair via MitraClip: Integrated assessment by two- and three-dimensional echocardiography.. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions. 2019. DOI: 10.1002/ccd.28147.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.