MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3174/ajnr.a3227

Медицинская библиотека · AJNR. American journal of neuroradiology · 2012

Head and neck tumors: assessment of perfusion-related parameters and diffusion coefficients based on the intravoxel incoherent motion model.

Sumi M, Nakamura T

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: IVIM MR imaging provides perfusion and diffusion information with a single diffusion-weighted MR image. We determined whether PP and D differ among various types of head and neck tumors.

MATERIALS AND

METHODS

The study cohort included 123 head and neck tumors: 30 SCCs, 28 benign and 20 malignant SG tumors, 36 lymphomas, and 9 schwannomas. The D and PP values were determined by using b-values of 0, 500, and 1000 s/mm(2) based on the IVIM model.

RESULTS

The PP values (lymphomas, 0.09 ± 0.04; SCCs, 0.15 ± 0.04; and malignant SG tumors, 0.22 ± 0.07) and D values (0.47 ± 0.07 × 10(-3) mm(2)/s, 0.82 ± 0.17 × 10(-3) mm(2)/s, and 1.03 ± 0.16 × 10(-3) mm(2)/s, respectively) were significantly different among the malignant tumors (P < .01). These values were also significantly different between pleomorphic adenomas (0.13 ± 0.02 and 1.44 ± 0.39 × 10(-3) mm(2)/s) and Warthin tumors (0.19 ± 0.04 and 0.73 ± 0.22 × 10(-3) mm(2)/s) (P < .001). The PP values of malignant SG tumors were significantly different from those of pleomorphic adenomas (P = .001) and the D values of the malignant SG tumors were significantly different from those of pleomorphic adenomas (P = .002) and Warthin tumors (P = .007). Schwannomas had large PP (0.23 ± 0.08) and D values (1.26 ± 0.20 × 10(-3) mm(2)/s), greatly overlapping those of some SG tumor types.

CONCLUSIONS

Head and neck tumors had distinctive PP and D values by using IVIM MR imaging.

Для цитирования: Sumi M, Nakamura T. Head and neck tumors: assessment of perfusion-related parameters and diffusion coefficients based on the intravoxel incoherent motion model.. AJNR. American journal of neuroradiology. 2012. DOI: 10.3174/ajnr.a3227.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.