MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carrev.2017.01.009

Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2017

A novel side branch protection technique in coronary stent implantation: Jailed Corsair technique.

Numasawa Yohei, Sakakura Kenichi, Yamamoto Kei, Yamamoto Shingo, Taniguchi Yousuke, Fujita Hideo, Momomura Shin-Ichi

Клинический случайСтатьяОбзорПеревод пока не подготовлен

Аннотация

Side branch occlusion, which was one of the common complications in percutaneous coronary interventions, was closely associated with cardiac death and myocardial infarction. Clinical guidelines also support the importance of preservation of physiologic blood flow in SB during PCI to bifurcation lesions. In order to avoid side branch occlusion during stent implantation, we often performed the jailed wire technique, in which a conventional guide wire was inserted to the side branch before stent implantation to the main vessel. However, the jailed wire technique could not always prevent side branch occlusion. In this case report, we described a case of 72-year-old male suffering from angina pectoris. Coronary angiography revealed the diffuse calcified stenosis in the proximal and middle of left anterior descending coronary artery, and the large diagonal branch originated from the middle of the stenosis. To prevent side branch occlusion, we performed a novel side branch protection technique by using the Corsair microcatheter (Asahi Intecc, Nagoya, Japan). In this case report, we illustrated this "Jailed Corsair technique", and discussed the advantage compared to other side branch protection techniques such as the jailed balloon technique.

Для цитирования: Numasawa Yohei, Sakakura Kenichi, Yamamoto Kei, Yamamoto Shingo, Taniguchi Yousuke, Fujita Hideo, Momomura Shin-Ichi. A novel side branch protection technique in coronary stent implantation: Jailed Corsair technique.. Cardiovascular revascularization medicine : including molecular interventions. 2017. DOI: 10.1016/j.carrev.2017.01.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.