MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1128/aac.00725-24

Медицинская библиотека · Antimicrobial agents and chemotherapy · 2024

Polymyxins retain in vitro activity and in vivo efficacy against "resistant" Acinetobacter baumannii strains when tested in physiological conditions.

Rubio Jennifer, Yan Jun, Miller Sarah, Cheng Jiaqi, Li Rachel, Builta Zac, Aoyagi Kari, Fisher Mark, She Rosemary, Spellberg Brad, Luna Brian

СтатьяПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

The emergence of plasmid-mediated resistance threatens the efficacy of polymyxins as the last line of defense against pan-drug-resistant infections. However, we have found that using Mueller-Hinton II (MHII), the standard minimum inhibitory concentration (MIC) medium, results in MIC data that are disconnected from in vivo treatment outcomes. We found that culturing putative colistin-resistant Acinetobacter baumannii clinical isolates, as defined by MICs of >2 mg/L in standard MHII testing conditions, in bicarbonate-containing media reduced MICs to the susceptible range by preventing colistin resistance-conferring lipopolysaccharide modifications from occurring. Furthermore, the lower MICs in bicarbonate-containing media accurately predicted in vivo efficacy of a human-simulated dosing strategy of colistin and polymyxin B in a lethal murine infection model for some polymyxin-resistant A. baumannii strains. Thus, current polymyxin susceptibility testing methods overestimate the contribution of polymyxin resistance-conferring mutations and incorrectly predict antibiotic activity in vivo. Polymyxins may remain a viable therapeutic option against Acinetobacter baumannii strains heretofore determined to be "pan-resistant."

Для цитирования: Rubio Jennifer, Yan Jun, Miller Sarah, Cheng Jiaqi, Li Rachel, Builta Zac, Aoyagi Kari, Fisher Mark, She Rosemary, Spellberg Brad, Luna Brian. Polymyxins retain in vitro activity and in vivo efficacy against "resistant" Acinetobacter baumannii strains when tested in physiological conditions.. Antimicrobial agents and chemotherapy. 2024. DOI: 10.1128/aac.00725-24.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.