MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00207454.2015.1134526

Медицинская библиотека · The International journal of neuroscience · 2016

Low antioxidant status of serum bilirubin, uric acid, albumin and creatinine in patients with myasthenia gravis.

Yang Dehao, Su Zhongqian, Wu Shengjie, Bi Yong, Li Xiang, Li Jia, Lou Kangliang, Zhang Hongyu, Zhang Xu

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Oxidative stress and low antioxidant status play a major role in the pathogenesis of inflammatory and autoimmune diseases. Myasthenia gravis (MG) is an autoimmune condition targeting the neuromuscular junction, and its antioxidant status is still controversial. Our study aimed to investigate the correlation between the clinical characteristics of MG and the serum antioxidant status of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine.

MATERIALS AND

METHODS

We measured serum antioxidant molecule levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine in 380 individuals, including 166 MG and 214 healthy controls.

RESULTS

We found that MG patients had significantly lower serum levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine than healthy controls, whether male or female. Moreover, it was also shown in our study that uric acid, albumin and creatinine levels in patients with MG were correlated with disease activity and classifications performed by the Myasthenia Gravis Foundation of America.

CONCLUSION

Our findings demonstrated that serum levels of bilirubin (Tbil, Dbil and Ibil), uric acid, albumin and creatinine were reduced in patients with MG. This suggested an active oxidative process in MG patients who had low antioxidant status.

Для цитирования: Yang Dehao, Su Zhongqian, Wu Shengjie, Bi Yong, Li Xiang, Li Jia, Lou Kangliang, Zhang Hongyu, Zhang Xu. Low antioxidant status of serum bilirubin, uric acid, albumin and creatinine in patients with myasthenia gravis.. The International journal of neuroscience. 2016. DOI: 10.3109/00207454.2015.1134526.