MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jdiacomp.2021.108106

Медицинская библиотека · Journal of diabetes and its complications · 2021

Randomized comparison of self-monitored blood glucose (BGM) versus continuous glucose monitoring (CGM) data to optimize glucose control in type 2 diabetes.

Bergenstal Richard M, Mullen Deborah M, Strock Ellie, Johnson Mary L, Xi Min X

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: Evaluate whether structured BGM testing (BGM) or real-time CGM (CGM) lead to improved glucose control (A1c). Determine which approach optimized glucose control more effectively. METHODS-MULTI-ARM PARALLEL: trial of three type 2 diabetes (T2D) therapies ± metformin: (1) sulfonylurea (SU), (2) incretin (DPP4 inhibitor or GLP-1 agonist), or (3) insulin. After a baseline CGM, 114 adult subjects were randomized to either BGM (4 times daily) or CGM (24/7) for 16 weeks with therapies adjusted every 4 weeks.

RESULTS

A1c means decreased from 8.19 to 7.07 (1.12% difference) with CGM (n = 59) and 7.85 to 7.03 (0.82% difference) with BGM (n = 55) (p < 0.001). BGM and CGM groups showed significant improvements in time in range and glucose variability-with no significant difference between the two groups. Clinically important hypoglycemia (<50 mg/dL) was significantly reduced for the CGM group compared with BGM (p < 0.01), particularly in subjects taking insulin or therapies with higher hypoglycemic risk (SU).

CONCLUSION

In T2D, structured, consistent use of glucose data regardless of device (structured BGM or CGM) leads to improvements in A1c control. CGM is more effective than BGM in minimizing hypoglycemia particularly for those using higher hypoglycemic risk therapies.

Для цитирования: Bergenstal Richard M, Mullen Deborah M, Strock Ellie, Johnson Mary L, Xi Min X. Randomized comparison of self-monitored blood glucose (BGM) versus continuous glucose monitoring (CGM) data to optimize glucose control in type 2 diabetes.. Journal of diabetes and its complications. 2021. DOI: 10.1016/j.jdiacomp.2021.108106.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.