BACKGROUND

Considering that ablation of atypical AVNRT may be unsuccessful after ablation at the right posterior septum, in this study, we aimed to present an optimal method for ablation of atypical AVNRT. Also, we evaluated the efficacy of this technique for preventing recurrences.

METHODS

This is a prospective, double-center study. It was conducted on 62 patients with atypical AVNRT referred for radiofrequency ablation. The patients were randomly divided into two groups before ablation: 1-Group A (n = 30): treated with conventional ablation at the anatomic area of the slow pathway; 2-Group B (n = 32): ablation was done 2 mm higher in the septum during fluoroscopy.

RESULTS

The mean age of patients in groups A and B were 54 ± 11.7 and 55 ± 12.2, respectively (P = 0.43). In group A, ablation was successful in 24 (80%) patients following right-sided slow pathway ablation, and the remaining patients required further treatment with either a left-side approach (N = 4, 13.3%) or ablation of additional regions (N = 2, 6.7%). In group B, ablation was successful in all patients. After a 48-month follow-up, recurrence of symptomatic atypical AVNRT was detected in 4 (13.3%) patients of group A and none of group B patients (p < 0.001).

CONCLUSION

In patients with atypical AVNRT, ablation 2 mm above the conventional area is more promising regarding success rate and recurrence of the arrhythmia.

Для цитирования: Aslani Amir, Shahrzad Shahab, Bazrafshan Mehdi, Rahmanian Mahdi, Fakhar Reza, Pirahesh Kasra, Bazrafshan Hanieh, Bazrafshan Hamed. Optimal method for ablation of atypical AVNRT.. BMC cardiovascular disorders. 2023. DOI: 10.1186/s12872-023-03305-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.