MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2023.04.044

Медицинская библиотека · International journal of cardiology · 2023

Multielectrode mapping for premature ventricular contraction ablation - A prospective, multicenter study.

Sousa Pedro A, Barra Sérgio, Cortez-Dias Nuno, Khoueiry Ziad, Paulo José, António Natália, Ferreira Afonso, Pereira Mariana, Lagrange Philippe, de Sousa Joao, Elvas Luís, Garcia Fermin C, Gonçalves Lino

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We aim to evaluate whether the use of a multielectrode mapping catheter could lead to higher efficacy of premature ventricular contraction (PVC) ablation.

METHODS

Prospective, multicenter nonrandomized study of consecutive patients referred for PVC ablation from January 2018 to June 2021. Patients were separated into two groups: activation map performed with the PentaRay catheter (Study group) or with the ablation catheter (Control group). PMF software was used in both groups. Procedural endpoints and 1-year freedom from ventricular arrhythmia were assessed.

RESULTS

During the enrollment period 136 patients (60% males, mean age of 55 ± 17 years, 60% left-sided origin) fulfilled the inclusion criteria - 68 patients in each group. Patients in the Study Group had a sevenfold higher number of acquired activation points (768 ± 728 vs. 110 ± 79, p < 0.01), a shorter mapping time (28 ± 19 min vs. 49 ± 32 min, p < 0.01) and a quicker procedure time (110 ± 33 min vs. 134 ± 50 min, p < 0.01), compared to patients in the Control Group. While there were no significant differences in the acute success (95.6% in the Study Group vs. 90.1% in Control group, p = 0.49), or adverse events (4% in the Study group vs. 7% in the Control group, p = 0.72), patients in the Study group had a higher freedom from ventricular arrhythmia at 1-year (89.7% vs. 70.6%, p = 0.01). The use of the PentaRay catheter was an independent predictor of success (HR = 6.20 [95% CI, 1.08-35.47], p = 0.003).

CONCLUSIONS

The use of the PentaRay catheter may improve the outcome of PVC ablation while reducing procedure time.

Для цитирования: Sousa Pedro A, Barra Sérgio, Cortez-Dias Nuno, Khoueiry Ziad, Paulo José, António Natália, Ferreira Afonso, Pereira Mariana, Lagrange Philippe, de Sousa Joao, Elvas Luís, Garcia Fermin C, Gonçalves Lino. Multielectrode mapping for premature ventricular contraction ablation - A prospective, multicenter study.. International journal of cardiology. 2023. DOI: 10.1016/j.ijcard.2023.04.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.