MedElevator Войти в исследования
← Поиск публикаций

DOI 10.24875/acm.22000090

Медицинская библиотека · Archivos de cardiologia de Mexico · 2023

Validation of qrs-polarity algorithm with special emphasis in parahisian pathways.

Gómez-Flores Jorge, Cueva-Parra Ángel, Gallegos-Cortéz Antonio, Nava Santiago, Márquez Manlio F, Iturralde-Torres Pedro

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In 1996 Iturralde et al. published an algorithm based on the QRS polarity to determine the location of the accessory pathways (AP), this algorithm was developed before the massive practice of invasive electrophysiology.

PURPOSE: To validate the QRS-Polarity algorithm in a modern cohort of subjects submitted to radiofrequency catheter ablation (RFCA). Our objective was to determinate its global accuracy and its accuracy for parahisian AP.

METHODS

We conducted a retrospective analysis of patients with Wolff-Parkinson-White (WPW) syndrome who underwent an electrophysiological study (EPS) and RFCA. We employed the QRS-Polarity algorithm to predict the AP anatomical location and we compared this result with the real anatomic location determined in the EPS. To determine accuracy, the Cohen's kappa coefficient (k) and the Pearson correlation coefficient were used.

RESULTS

A total of 364 patients were included (mean age 30 years, 57% male). The global k score was 0.78 and the Pearson's coefficient was 0.90. The accuracy for each zone was also evaluated, the best correlation was for the left lateral AP (k of 0.97). There were 26 patients with a parahisian AP, who showed a great variability in the ECG features. Employing the QRS-Polarity algorithm, 34.6% patients had a correct anatomical location, 42.3% had an adjacent location and only 23% an incorrect location.

CONCLUSION

The QRS-Polarity algorithm has a good global accuracy; its precision is high, especially for left lateral AP. This algorithm is also useful for the parahisian AP.

Для цитирования: Gómez-Flores Jorge, Cueva-Parra Ángel, Gallegos-Cortéz Antonio, Nava Santiago, Márquez Manlio F, Iturralde-Torres Pedro. Validation of qrs-polarity algorithm with special emphasis in parahisian pathways.. Archivos de cardiologia de Mexico. 2023. DOI: 10.24875/acm.22000090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.