Aortic dimensions by multi-detector computed tomography vs. echocardiography.

Blondheim David S, Vassilenko Lubov, Glick Yair, Asif Aya, Nachtigal Alicia, Meisel Simcha R, Shochat Michael, Shotan Avraham, Zeina Abdel-Rauf

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Clinical follow-up of aortic dimensions is performed interchangeably by multi-detector computed tomography (MDCT) and by cardiac echocardiography (ECHO). This study assesses the relationship between measurements of the aortic diameter by MDCT and ECHO at various predetermined locations using several methods.

METHODS

The aortic diameter was measured at 6 locations between the aortic annulus and the aortic arch in 49 patients who underwent both MDCT and ECHO. Measurements were performed by three methods: internal-to-internal edge (INT), external-to-internal edge (MIX), and external-to-external edge (EXT). Measurements by MDCT and ECHO were made by an experienced radiologist and cardiologist, respectively, both blinded to results and images from the other modality.

RESULTS

The average aortic diameter at all locations was significantly different between the MDCT and ECHO by all three methods (INT: 30.0±5.8mm vs. 27.8±5.9mm; MIX: 31.5±5.8mm vs. 30.8±5.8mm; EXT: 32.9±6.6mm vs. 33.8±6.5mm, p<0.002 for all). While mean absolute differences between INT and EXT methods were similar (3.5±3.1mm and 3.4±2.7mm, respectively), the absolute difference using the MIX method was significantly smaller (3.1±2.8mm; p<0.001 for INT vs. MIX; p<0.05 for EXT vs. MIX).

CONCLUSIONS

There is considerable variability between MDCT and ECHO measurements of the ascending aorta. Measuring the aortic diameter by the MIX provides the closest measurements and is advised for long-term follow-up.

Для цитирования: Blondheim David S, Vassilenko Lubov, Glick Yair, Asif Aya, Nachtigal Alicia, Meisel Simcha R, Shochat Michael, Shotan Avraham, Zeina Abdel-Rauf. Aortic dimensions by multi-detector computed tomography vs. echocardiography.. Journal of cardiology. 2015. DOI: 10.1016/j.jjcc.2015.06.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.