MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0035-1554043

Медицинская библиотека · The Thoracic and cardiovascular surgeon · 2015

Sutureless Valve Implantation via Mini J-Sternotomy: A Single Center Experience with 2 Years Mean Follow-up.

Fischlein Theodor, Pfeiffer Steffen, Pollari Francesco, Sirch Joachim, Vogt Ferdinand, Santarpino Giuseppe

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Despite increased operative time, minimally invasive cardiac surgery is associated with a lower morbidity than conventional aortic valve replacement (AVR). On the other hand, sutureless aortic bioprostheses have the potential of simplifying implantation, as it reduces the ischemic time. Our aim was to investigate the outcome of a sutureless AVR through a mini-sternotomy.

MATERIALS AND

METHODS

Since March 2010, a total of 262 patients affected by aortic valve stenosis underwent AVR with a sutureless bioprosthesis (Perceval, Sorin Group, Saluggia, Italy). Of these, 145 patients (mean age 77.8 ± 4.7 years, 80 women) underwent surgical AVR through a mini J-sternotomy. Clinical and echocardiographic data were evaluated.

RESULTS

Patients received a size: S(12), M(49), L(67), or XL(17) prostheses, either as isolated (131) or combined procedures (14) including 2 redo patients who had undergone coronary artery bypass grafting via full sternotomy previously. Mean logistic EuroSCORE (I) was 9.9 ± 5.9%, and mean aortic cross-clamp time was 38 ± 12 minutes (35 ± 11 minutes in isolated procedures). Two conversions to full sternotomy were necessary because of bleeding. Thirty-day mortality was 2.1% (all noncardiac deaths); mean hospital stay was 11.6 ± 4.9 days. We recorded 11 pacemaker implantations (7.6%). At follow-up (23.5 ± 14.4 months), five patients were dead (three noncardiac and two cardiac deaths). At echocardiographic control, mean transprosthetic gradients were as follows: 12.8 ± 4.9, 12.5 ± 4.5, 11.8 ± 4.7 mm Hg, postoperatively at 6 months, 1 year, and 2 years, respectively. No paravalvular leaks were recorded.

CONCLUSION

The sutureless bioprosthesis shows satisfactory clinical and hemodynamic results. Owing to its simple implantation technique, it represents a good support for minimally invasive access surgery via J-sternotomy.

Для цитирования: Fischlein Theodor, Pfeiffer Steffen, Pollari Francesco, Sirch Joachim, Vogt Ferdinand, Santarpino Giuseppe. Sutureless Valve Implantation via Mini J-Sternotomy: A Single Center Experience with 2 Years Mean Follow-up.. The Thoracic and cardiovascular surgeon. 2015. DOI: 10.1055/s-0035-1554043.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.