m+Medelevator.RU
← Поиск публикаций
International journal of cardiology · 2015

Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement.

Сравнительное исследованиеСтатьяМетаанализНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Agarwal Shikhar, Parashar Akhil, Kumbhani Dharam J, Svensson Lars G, Krishnaswamy Amar, Tuzcu E Murat, Kapadia Samir R

Аннотация

BACKGROUND: Balloon-expandable valves (BEVs) and self-expandable valves (SEVs) are two major types of valves utilized for transcatheter aortic valve replacement (TAVR). We conducted a meta-analysis of available studies to compare the safety and efficacy of these two valve types.

METHODS: Medline search was conducted using standard search terms to determine eligible studies. Primary outcomes of the meta-analysis included death and stroke at 30days and 1year. Pooled estimates of procedural outcomes were also compared between the valve types. Analysis was performed for entire cohort and separately for patients undergoing transfemoral TAVR (TF-TAVR).

RESULTS: Analysis of entire cohort revealed similar 30-day mortality in the SEV and BEV cohorts. There was no significant difference in the incidence of stroke at 30days between the two study groups. Both pooled comparisons demonstrated a significant heterogeneity with I(2)>50%, necessitating the use of random effect modeling. We observed a significantly higher incidence of new pacemaker implantation, aortic regurgitation≥2+ at 30days, valve embolization, and need for >1 valve following SEV implantation compared with BEV implantation. Analysis of TF-TAVR cohort showed higher 30day [IRR (95% CI): 1.34 (1.19-1.52)] but a similar 1-year mortality [IRR (95% CI): 1.07 (0.96-1.19)] for SEV compared to BEV implantation.

CONCLUSION: Compared to BEV implantation, SEV implantation was associated with a similar risk of mortality and stroke at 30-day and 1-year follow-up duration. Analysis of the TF-TAVR cohort revealed a significantly higher mortality at 30days among patients undergoing SEV implantation, compared with BEV implantation. In addition, there was a significantly higher incidence of other adverse events noted above, following SEV implantation, compared with BEV implantation.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты