m+Medelevator.RU
← Поиск публикаций
Journal of electrocardiology · 1994

Automated analysis of spontaneously occurring arrhythmias by implantable devices. Limitations of using rate and timing features alone.

СтатьяПоддержка исследования: вне правительства СШАПоддержка правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Caswell S A, DiCarlo L A, Chiang C M, Jenkins J M

Аннотация

Real-time automated systems for arrhythmia analysis by implantable antitachycardia devices have been designed to incorporate two-channel rate criteria with intracavitary atrial and ventricular electrogram morphology. Because the power requirements for morphologic analysis substantially limit antitachycardia device longevity, the authors sought to develop an alternative algorithm that relies solely on rate and three newly developed timing features: onset (median ventricular rate filtering to detect abrupt onset), loss of atrioventricular (AV) sequency (premature ventricular depolarizations), and regularity-multiplicity (minimal median cycle length variation concurrent with integral [n:1] AV periodicity). This system was assessed using spontaneously occurring arrhythmias in patients undergoing electrophysiology studies. Electrograms were captured on FM tape (1-500 Hz) using biopolar catheters in the high right atrium and the left ventricular apex. In 11 patients, 25 distinct arrhythmias were analyzed, which included sinus tachycardia (ST) (1 passage), supraventricular tachycardia (SVT) (6 passages), ventricular tachycardia (VT) with concurrent sinus rhythm (16 passages), VT with concurrent atrial flutter (VT/AFl) (2 passages), and ventricular fibrillation (VF) (1 passage). The algorithm correctly diagnosed 1 of 1 episode of ST, 4 of 6 episodes of SVT, 15 of 16 episodes of VT with concurrent sinus rhythm, 0 of 2 episodes of VT/AFl, and 1 of 1 episode of VF. Ventricular tachycardia episodes were misdiagnosed as SVT because of absence of loss of AV sequency in VT onset (1 episode), presence of multiplicity between VT and AFl (1 episode), and absence of VT regularity during AFl (1 episode).(ABSTRACT TRUNCATED AT 250 WORDS)

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты