MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/iae.0000000000004229

Медицинская библиотека · Retina (Philadelphia, Pa.) · 2025

A NEW TECHNIQUE OF STERILE POLYETHYLENE INSTRUMENT COVER AS TEMPORARY CORNEAL PATCH TO RECONSTRUCT ANTERIOR CHAMBER IN PENETRATING KERATOPLASTY COMBINED WITH INTRAOCULAR SURGERY.

Long Jianfeng, Li Haoyu, Zhang Liwei, Sun Xinyue, Liu Shaohua, Peng Hanhan, Chen Baihua

СтатьяКлинический случайПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: Complications such as explosive choroidal hemorrhage, residual cortex, and capsule rupture often occur during intraocular surgery combined with penetrating keratoplasty (PKP) due to poor maintenance of the anterior chamber. To address these challenges, the authors have innovatively used a sterile polyethylene instrument cover to temporarily reconstruct the anterior chamber.

METHODS

In this report, the authors describe a technique where a "temporary corneal patch" was created from a sterile instrument cover, using a trephine to ensure a diameter approximately 1 mm to 2 mm wider than the corneal bed or perforation. This patch was then sutured into the host corneal bed or the perforation with 10-0 nylon sutures during intraocular surgery combined with PKP. Each case was evaluated for surgical efficacy and complications.

RESULTS

The authors successfully applied this technique in three cases of combined corneal transplantation surgery. In two cases, PKP, phacoemulsification, and intraocular lens implantation were successfully performed. In the third case, PKP, vitrectomy, and other intraocular procedures were performed. No intraoperative or postoperative complications were observed.

CONCLUSION

The use of a sterile polyethylene material as a temporary corneal patch for anterior chamber reconstruction represents a safe, effective, and cost-efficient approach for intraocular surgery combined with PKP or posterior segment surgery as a keratoprosthesis.

Для цитирования: Long Jianfeng, Li Haoyu, Zhang Liwei, Sun Xinyue, Liu Shaohua, Peng Hanhan, Chen Baihua. A NEW TECHNIQUE OF STERILE POLYETHYLENE INSTRUMENT COVER AS TEMPORARY CORNEAL PATCH TO RECONSTRUCT ANTERIOR CHAMBER IN PENETRATING KERATOPLASTY COMBINED WITH INTRAOCULAR SURGERY.. Retina (Philadelphia, Pa.). 2025. DOI: 10.1097/iae.0000000000004229.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.