MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2011.03.016

Медицинская библиотека · JACC. Cardiovascular interventions · 2011

Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 1).

Piazza Nicolo, Bleiziffer Sabine, Brockmann Gernot, Hendrick Ruge, Deutsch Marcus-André, Opitz Anke, Mazzitelli Domenico, Tassani-Prell Peter, Schreiber Christian, Lange Rüdiger

СтатьяОбзорПеревод пока не подготовлен

Аннотация

With an aging population, improvement in life expectancy, and significant increase in the use of bioprosthetic valves, structural valve deterioration will become more and more prevalent. The operative mortality for an elective redo aortic valve surgery is reported to range from 2% to 7%, but this percentage can increase to more than 30% in high-risk and nonelective patients. Because transcatheter aortic valve (TAV)-in-surgical aortic valve (SAV) implantation represents a minimally invasive alternative to conventional redo surgery, it may prove to be safer and just as effective as redo surgery. Of course, prospective comparisons with a large number of patients and long-term follow-up are required to confirm these potential advantages. It is axiomatic that knowledge of the basic construction and dimensions, radiographic identification, and potential failure modes of SAV bioprostheses is fundamental in understanding key principles involved in TAV-in-SAV implantation. The goals of this paper are: 1) to review the classification, physical characteristics, and potential failure modes of surgical bioprosthetic aortic valves; and 2) to discuss patient selection and procedural techniques relevant to TAV-in-SAV implantation.

Для цитирования: Piazza Nicolo, Bleiziffer Sabine, Brockmann Gernot, Hendrick Ruge, Deutsch Marcus-André, Opitz Anke, Mazzitelli Domenico, Tassani-Prell Peter, Schreiber Christian, Lange Rüdiger. Transcatheter aortic valve implantation for failing surgical aortic bioprosthetic valve: from concept to clinical application and evaluation (part 1).. JACC. Cardiovascular interventions. 2011. DOI: 10.1016/j.jcin.2011.03.016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.