Reoperation for mid-term failure of a freestyle bioprosthesis using a full root technique --a surgical case--.
Аннотация
The aortic root of a 30-year-old man was replaced with a Freestyle stentless aortic bioprosthesis for aortic regurgitation associated with annuloaortic ectasia. His clinical course was uneventful, and he was discharged without complications. Three years and six months after surgery, he presented with a high fever. Four years after surgery, transthoracic echocardiography revealed severe aortic regurgitation. We performed exploratory surgery and discovered a torn left coronary cusp of the Freestyle bioprosthesis. Organized vegetation was adherent to the left coronary cusp leaflet. The non-coronary cusp and the right coronary cusp were normal. The diagnosis was aortic regurgitation due to valve failure related to infective endocarditis. Consequently, we reconstructed the aortic root with a composite graft (26-mm Valsalva graft and a 21-mm ON-X mechanical valve).
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.