Closure of a para-valvular aortic leak: with the use of 2 AMPLATZER devices and real-time 2- and 3-dimensional transesophageal echocardiography.
Аннотация
Paravalvular leaks are well-recognized sequelae of mechanical aortic valve implantation. Clinical manifestations include hemolysis, arrhythmias, and congestive heart failure. Frequently, patients who receive mechanical aortic valves are poor candidates for repeat valve surgery, and the reoperative mortality rate is high. Percutaneous intervention has recently become an alternative to surgery in selected patients. Herein, we describe the percutaneous closure of an aortic paravalvular leak in a 45-year-old man who had undergone 2 aortic valve replacements with mechanical valves. The patient, who was at high surgical risk due to comorbidities, underwent the implantation of 2 AMPLATZER devices with the use of real-time 2- and 3-dimensional transesophageal echocardiography. The early outcome of the procedure was favorable and without sequelae. To our knowledge, this is the 1st report of the closing of an aortic paravalvular leak with the use of 2 closure devices and real-time echocardiographic guidance.