Utility of a Simple and Robust Flow Cytometry Assay for Rapid Clonality Testing in Mature Peripheral T-Cell Lymphomas.

Novikov Natasha D, Griffin Gabriel K, Dudley Graham, Drew Mai, Rojas-Rudilla Vanesa, Lindeman Neal I, Dorfman David M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Flow cytometry immunophenotyping is limited by poor resolution of T-cell clones. A newly described antibody was recently used to distinguish normal peripheral blood T cells from malignant T-cell clones. Here, we evaluate this antibody as a new diagnostic tool for detecting T-cell clonality in mature peripheral T-cell lymphomas.

METHODS

Immunostaining for the T-cell receptor β chain constant region 1 (TRBC1) along with routine T-cell markers was performed on 51 peripheral blood and two bone marrow samples submitted to the flow cytometry laboratory for suspected T-cell malignancy.

RESULTS

TRBC immunophenotyping identified malignant T-cell clones with 97% sensitivity and 91% specificity. Findings correlated with molecular T-cell clonality testing. In cases with equivocal molecular results, TRBC1 immunophenotyping provided additional diagnostic information.

CONCLUSIONS

TRBC1 flow cytometric immunophenotyping is a robust and inexpensive method for identifying T-cell clonality that could easily be incorporated into routine flow cytometric practice.

Для цитирования: Novikov Natasha D, Griffin Gabriel K, Dudley Graham, Drew Mai, Rojas-Rudilla Vanesa, Lindeman Neal I, Dorfman David M. Utility of a Simple and Robust Flow Cytometry Assay for Rapid Clonality Testing in Mature Peripheral T-Cell Lymphomas.. American journal of clinical pathology. 2019. DOI: 10.1093/ajcp/aqy173.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.