MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2021.12.013

Медицинская библиотека · JACC. Clinical electrophysiology · 2022

Functional Assessment of Ventricular Tachycardia Circuits and Their Underlying Substrate Using Automated Conduction Velocity Mapping.

Hawson Joshua, Anderson Robert D, Al-Kaisey Ahmed, Chieng David, Segan Louise, Watts Troy, Campbell Timothy, Morton Joseph, McLellan Alexander, Kistler Peter, Voskoboinik Aleksander, Pathik Bhupesh, Kumar Saurabh, Kalman Jonathan, Lee Geoffrey

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to describe the utility of automated conduction velocity mapping (ACVM) in ventricular tachycardia (VT) ablation.

BACKGROUND

Identification of areas of slowed conduction velocity (CV) is critical to our understanding of VT circuits and their underlying substrate. Recently, an ACVM called Coherent Mapping (Biosense Webster Inc) has been developed for atrial mapping. However, its utility in VT mapping has not been described.

METHODS

Patients with paired high-density VT activation and substrate maps were included. ACVM was applied to paired VT activation and substrate maps to assess regional CV and activation patterns. A combination of ACVM, traditional local activation time maps, electrogram analysis, and off-line calculated CV using triangulation were used to characterize zones of slowed conduction during VT and in substrate mapping.

RESULTS

Fifteen patients were included in the study. In all cases, ACVM identified slow CV within the putative VT isthmus, which colocalized to the VT isthmus identified with entrainment. The dimensions of the VT isthmus with local activation time mapping were 37.8 ± 13.7 mm long and 8.7 ± 4.2 mm wide. In comparison, ACVM produced an isthmus that was shorter (length: 25.1 ± 10.6 mm; mean difference: 12.8; 95% CI: 7.5-18.0; P < 0.01) and wider (width: 18.8 ± 8.1 mm; mean difference: 10.1; 95% CI: 6.1-14.2; P < 0.01). In VT, the CV using triangulation at the entrance (8.0 ± 3.6 cm/s) and midisthmus (8.1 ± 4.3 cm/s) was not significantly different (P = 0.92) but was significantly faster at the exit (16.2 ± 9.7 cm/s; P < 0.01). In the paired substrate analysis, traditional local activation time isochronal mapping identified 6.3 ± 2.0 deceleration zones. In contrast, ACVM identified a median of 0 deceleration zones (IQR: 0-1; P < 0.01).

CONCLUSIONS

ACVM is a novel complementary tool that can be used to accurately resolve complex VT circuits and identify slow conduction zones in VT but has limited accuracy in identifying slowed conduction during substrate-based mapping.

Для цитирования: Hawson Joshua, Anderson Robert D, Al-Kaisey Ahmed, Chieng David, Segan Louise, Watts Troy, Campbell Timothy, Morton Joseph, McLellan Alexander, Kistler Peter, Voskoboinik Aleksander, Pathik Bhupesh, Kumar Saurabh, Kalman Jonathan, Lee Geoffrey. Functional Assessment of Ventricular Tachycardia Circuits and Their Underlying Substrate Using Automated Conduction Velocity Mapping.. JACC. Clinical electrophysiology. 2022. DOI: 10.1016/j.jacep.2021.12.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.