Safabakhsh Sina, Du Darson, Liew Janet, Parker Jeremy, McIlroy Cheryl, Khasanova Elina, Indraratna Praveen, Blanke Philipp, Leipsic Jonathon, Andrade Jason G, Bennett Matthew T, Hawkins Nathaniel M, Chakrabarti Shantabanu, Yeung John, Deyell Marc W, Krahn Andrew D, Moss Robert, Ong Kevin, Laksman Zachary
Аннотация
BACKGROUND: Sudden cardiac death (SCD) risk stratification in hypertrophic cardiomyopathy (HCM) currently relies on arrhythmic burden quantification by 24 or 48-hour Holter monitoring. Whether this approach adequately captures arrhythmic burden, compared with longer-term continuous monitoring, is unclear. We sought to assess the long-term incidence of nonsustained ventricular tachycardia (NSVT) in HCM patients at low or moderate SCD risk, using implantable cardiac monitors (ICMs) paired with a novel Bluetooth-enabled 2-way communication platform.
METHODS: This prospective, single-arm, observational study enrolled 33 HCM patients. Patients were implanted with an Abbott (Chicago, IL) Confirm Rx ICM and monitored using a protocolized care pathway.
RESULTS: A total of 20 patients (60.6%) had ≥ 1 episode of NSVT recorded on the ICM, the majority of whom had previous Holter monitors that did not identify NSVT (60%, n = 12). A total of 71 episodes of NSVT were detected. Median time to first NSVT detection was 76.5 days (range: 0-553 days). A total of 19 patients underwent primary prevention implantable cardioverter defibrillator implantation during an average follow-up of 544 days (range: 42-925 days). A total of 172,112 automatic transmissions were received, and 65 (0.04%) required clinical follow-up. A total of 325 manual transmissions were received and managed. A total of 14 manual transmissions (4.3%) required follow-up, whereas 311 (95.7%) were managed solely with a text message.
CONCLUSIONS: Surveillance and reporting systems utilizing 2-way communication enabled by novel ICMs are feasible and allow remote management of patients with HCM. Prolonged monitoring with ICMs identified more patients with nonsustained arrythmias than did standard Holter monitoring. In many cases, this information impacted both SCD risk stratification and patient management.
METHODS: This prospective, single-arm, observational study enrolled 33 HCM patients. Patients were implanted with an Abbott (Chicago, IL) Confirm Rx ICM and monitored using a protocolized care pathway.
RESULTS: A total of 20 patients (60.6%) had ≥ 1 episode of NSVT recorded on the ICM, the majority of whom had previous Holter monitors that did not identify NSVT (60%, n = 12). A total of 71 episodes of NSVT were detected. Median time to first NSVT detection was 76.5 days (range: 0-553 days). A total of 19 patients underwent primary prevention implantable cardioverter defibrillator implantation during an average follow-up of 544 days (range: 42-925 days). A total of 172,112 automatic transmissions were received, and 65 (0.04%) required clinical follow-up. A total of 325 manual transmissions were received and managed. A total of 14 manual transmissions (4.3%) required follow-up, whereas 311 (95.7%) were managed solely with a text message.
CONCLUSIONS: Surveillance and reporting systems utilizing 2-way communication enabled by novel ICMs are feasible and allow remote management of patients with HCM. Prolonged monitoring with ICMs identified more patients with nonsustained arrythmias than did standard Holter monitoring. In many cases, this information impacted both SCD risk stratification and patient management.