MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/10926429251408805

Медицинская библиотека · Journal of laparoendoscopic & advanced surgical techniques. Part A · 2026

An Exploratory Randomized Controlled Trial Comparing Ultrasonic Dissection and Monopolar Electrocautery in Single-Incision Laparoscopic Totally Extraperitoneal Inguinal Hernia Repair.

Nakahara Yujiro, Iwamoto Kazuya, Takaichi Shohei, Paku Masakatsu, Ohashi Tomofumi, Takahashi Hidekazu, Asaoka Tadafumi, Matsuda Chu, Omori Takeshi, Nishikawa Kazuhiro, Takemasa Ichiro, Mizushima Tsunekazu

СтатьяРандомизированное исследованиеСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: This exploratory study aimed to compare the surgical outcomes of ultrasonic dissection and monopolar electrocautery in single-incision laparoscopic totally extraperitoneal repair (SILS-TEP) for inguinal hernia.

METHODS

A single-center exploratory randomized controlled trial was conducted between July 2022 and December 2023, enrolling 62 patients with unilateral inguinal hernias. Patients were randomized to undergo SILS-TEP using ultrasonic dissection (U group, n = 30) or monopolar electrocautery (E group, n = 32). The primary outcome was the completion rate of SILS-TEP. Secondary outcomes included the intraoperative complication rate, operative time, blood loss, and postoperative complication rate.

RESULTS

Patient characteristics were similar, except for a higher proportion of right-sided hernias in the U group (66.7% versus 31.3%, P = .010). Completion rates were comparable (96.7% versus 96.9%, P = 1.00). Operative time (60 [interquartile range {IQR} 53.5-71.5] minutes versus 62.5 [IQR: 51-74.5] minutes, P = .72) and blood loss were also similar. Lens cleaning was more frequently required in the U group (4 [IQR: 2.5-5] times versus 1 [IQR: 1-4] time, P = .025). Intraoperative and postoperative complications, length of postoperative hospital stay, and recurrence rates showed no notable differences.

CONCLUSION

In this exploratory analysis, monopolar electrocautery in SILS-TEP showed comparable surgical outcomes to ultrasonic dissection. Larger confirmatory studies are warranted to validate these findings. (UMIN000057091).

Для цитирования: Nakahara Yujiro, Iwamoto Kazuya, Takaichi Shohei, Paku Masakatsu, Ohashi Tomofumi, Takahashi Hidekazu, Asaoka Tadafumi, Matsuda Chu, Omori Takeshi, Nishikawa Kazuhiro, Takemasa Ichiro, Mizushima Tsunekazu. An Exploratory Randomized Controlled Trial Comparing Ultrasonic Dissection and Monopolar Electrocautery in Single-Incision Laparoscopic Totally Extraperitoneal Inguinal Hernia Repair.. Journal of laparoendoscopic & advanced surgical techniques. Part A. 2026. DOI: 10.1177/10926429251408805.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.