DOI 10.1097/hjh.0b013e32834c31db
Metronomic breathing shows altered parasympathetic baroreflex function in untreated Fabry patients and baroreflex improvement after enzyme replacement therapy.
Аннотация
OBJECTIVE
In untreated Fabry patients without overt autonomic dysfunction and normal baroreflex sensitivity (BRS) at rest, BRS is impaired during orthostatic, sympathetic challenge but normalizes after enzyme-replacement therapy (ERT) (Hilz et al., J Hypertens 2010; 28:1438-1448). This study evaluated BRS during parasympathetic challenge with six cycles per minute metronomic deep breathing (MDB) in Fabry patients before and after ERT.
METHODS
In 22 Fabry patients (28 ± 8 years), we monitored RR-intervals (RRIs), SBP, and respiratory frequency during spontaneous breathing (spont_breath) and MDB, before and after 18 (11 patients) or 23 months (11 patients) of biweekly ERT (1.0 mg/kg agalsidase beta). We determined spectral powers of mainly sympathetic low-frequency (0.04-0.15 Hz) RRI fluctuations, parasympathetic high-frequency (0.15-0.5 Hz) RRI fluctuations, sympathetically mediated low-frequency powers of SBP and high-frequency powers of SBP. We calculated BRS (ms/mmHg) during spont_breath and MDB as low-frequency-high-frequency alpha index (coherence >0.5). We compared parameters during spont_breath and MDB within and between patients before and after ERT and 15 age-matched (27 ± 5 years) healthy men (RANOVA and posthoc analysis; significance: P < 0.05).
RESULTS
During spont_breath and MDB, parameters were similar between groups. Within the three groups, RRIs were lower, whereas RRI low-frequency powers and SBP low-frequency powers were higher during MDB than during spont_breath. BRS was similar during MBD and spont_breath in untreated patients (P > 0.05), but increased significantly with MDB in patients after ERT (P = 0.048) and in controls (P = 0.035).
CONCLUSION
In untreated Fabry patients, MDB uncovers impaired BRS. After 18 or 23 months of ERT, MDB-induced BRS increase is similar in Fabry patients and controls, demonstrating that ERT not only restores sympathetic but also parasympathetic baroreflex activation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.