MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0267659118789051

Медицинская библиотека · Perfusion · 2018

A comparison of haemostatic biomarkers during low-risk patients undergoing cardiopulmonary bypass using either conventional centrifugal cell salvage or the HemoSep device.

Boyle Gethin, Kuffel Agnieszka, Parmar Kiran, Gibson Kirsty, Smith Megan, Grehan Aidan, Hunt Beverley J, Chambers David J

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Cardiac surgery using cardiopulmonary bypass (CPB) is associated with a coagulopathy due to haemodilution, thrombocytopenia and platelet dysfunction and the activation of coagulation and fibrinolysis, despite the use of large doses of unfractionated heparin. Conventional red cell salvage may exacerbate post-operative bleeding as plasma containing haemostatic factors is discarded. We hypothesized that a novel cell salvage device (HemoSep) may attenuate haemostatic changes associated with red cell salvage. We studied haemostatic markers following autologous transfusion from conventional cell salvage or the HemoSep device.

METHODS

This randomised, controlled trial compared haemostatic markers in patients undergoing coronary artery bypass grafting or aortic valve replacement who received autologous blood returned from cell salvage (control) or HemoSep (study). Blood samples were taken pre-operatively, end of CPB, post-transfusion of salvaged blood and 3 hours post-operatively and analysed for full blood count (FBC), prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen, D-dimer and endogenous thrombin potential (ETP).

RESULTS

Fifty-four patients were recruited (n=28 control, n=26 study). Processed blood volume for transfusion was significantly (p<0.001) higher in the HemoSep group. In the HemoSep group, the PT was shorter (18.7±0.3 vs 19.9±0.3 sec; p<0.05) post-operatively and the aPTT was longer (48.6±3.8 vs 37.3±1.0 sec; p<0.01) following autologous transfusion. In the control group, D-dimer and ETP levels were higher (1903±424 vs.1088±151; p<0.05 and 739±46 vs. 394±60; p<0.001, respectively) following autologous transfusion.

CONCLUSIONS

Although centrifuged cell salvage is known to adequately haemoconcentrate and remove unwanted substrates and bacteriological contamination, the process can exacerbate coagulopathy. The HemoSep device demonstrated some increase in haemostatic markers when used in low-risk cardiac surgery patients.

Для цитирования: Boyle Gethin, Kuffel Agnieszka, Parmar Kiran, Gibson Kirsty, Smith Megan, Grehan Aidan, Hunt Beverley J, Chambers David J. A comparison of haemostatic biomarkers during low-risk patients undergoing cardiopulmonary bypass using either conventional centrifugal cell salvage or the HemoSep device.. Perfusion. 2018. DOI: 10.1177/0267659118789051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.