MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10544-011-9511-0

Медицинская библиотека · Biomedical microdevices · 2011

A microfluidic device with fluorimetric detection for intracellular components analysis.

Kwapiszewski Radosław, Skolimowski Maciej, Ziółkowska Karina, Jędrych Elżbieta, Chudy Michał, Dybko Artur, Brzózka Zbigniew

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

An integrated microfluidic system that coupled lysis of two cell lines: L929 fibroblasts and A549 epithelial cells, with fluorescence-based enzyme assay was developed to determine β-glucocerebrosidase activity. The microdevice fabricated in poly(dimethylsiloxane) consists of three main parts: a chemical cell lysis zone based on the sheath flow geometry, a micromeander and an optical fibers detection zone. Unlike many methods described in literature that are designed to analyse intracellular components, the presented system enables to perform enzyme assays just after cell lysis process. It reduces the effect of proteases released in lysis process on determined enzymes. Glucocerebrosidase activity, the diagnostic marker for Gaucher's disease, is the most commonly measured in leukocytes and fibroblasts using 4-methylumbelliferyl-β-D-glucopyranoside as synthetic β-glucoside. The enzyme cleavage releases the fluorescent product, i.e. 4-methylumbelliferone, and its fluorescence is measured as a function of time. The method of enzyme activity determination described in this paper was adapted for flow measurements in the microdevice. The curve of the enzymatic reaction advancement was prepared for three reaction times obtained from application of different flow rates of solutions introduced to the microsystem. Afterwards, determined β-glucocerebrosidase activity was recalculated with regard to 10(5) cells present in samples used for the tests. The obtained results were compared with a cuvette-based measurements. The lysosomal β-glucosidase activities determined in the microsystem were in good correlation with the values determined during macro-scale measurements.

Для цитирования: Kwapiszewski Radosław, Skolimowski Maciej, Ziółkowska Karina, Jędrych Elżbieta, Chudy Michał, Dybko Artur, Brzózka Zbigniew. A microfluidic device with fluorimetric detection for intracellular components analysis.. Biomedical microdevices. 2011. DOI: 10.1007/s10544-011-9511-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.